Austrian Patient Summary (R4)
0.1.0 - ci-build
Austrian Patient Summary (R4) - Local Development build (v0.1.0) built by the FHIR (HL7® FHIR® Standard) Build Tools. See the Directory of published versions
Active as of 2025-01-29 |
{
"resourceType" : "ValueSet",
"id" : "at-ips-immunization-vacine-codes",
"meta" : {
"profile" : [
🔗 "http://hl7.org/fhir/StructureDefinition/shareablevalueset"
]
},
"text" : {
"status" : "generated",
"div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p class=\"res-header-id\"><b>Generated Narrative: ValueSet at-ips-immunization-vacine-codes</b></p><a name=\"at-ips-immunization-vacine-codes\"> </a><a name=\"hcat-ips-immunization-vacine-codes\"> </a><a name=\"at-ips-immunization-vacine-codes-de-AT\"> </a><p>This value set includes codes based on the following rules:</p><ul><li>Include codes from<a href=\"http://www.snomed.org/\"><code>http://snomed.info/sct</code></a> where concept is-a 787482006 (No known immunizations)</li><li>Include codes from<a href=\"http://www.snomed.org/\"><code>http://snomed.info/sct</code></a> where concept is-a 787859002 (Vaccine product)</li><li>Import all the codes that are contained in https://termgit.elga.gv.at/ValueSet/eimpf-immunizationtarget</li></ul></div>"
},
"url" : "https://fhir.hl7.at/elga-austrianpatientsummary-r4/ValueSet/at-ips-immunization-vacine-codes",
"version" : "0.1.0",
"name" : "AtIpsImmunizationVacineCodes",
"title" : "AT IPS Immunitzation Vacine Codes",
"status" : "active",
"experimental" : true,
"date" : "2025-01-29T12:34:29+00:00",
"publisher" : "ELGA GmbH",
"contact" : [
{
"name" : "ELGA GmbH",
"telecom" : [
{
"system" : "url",
"value" : "https://elga.gv.at"
}
]
}
],
"description" : "This value set extens the existing vaccine codes from ELGA GmbH.",
"jurisdiction" : [
{
"coding" : [
{
"system" : "urn:iso:std:iso:3166",
"code" : "AUT"
}
]
}
],
"immutable" : false,
"copyright" : "This value set includes content from SNOMED CT, which is copyright © 2002+ International Health Terminology Standards Development Organisation (IHTSDO), and distributed by agreement between IHTSDO and HL7. Implementer use of SNOMED CT is not covered by this agreement",
"compose" : {
"include" : [
{
"system" : "http://snomed.info/sct",
"filter" : [
{
"property" : "concept",
"op" : "is-a",
"value" : "787482006"
}
]
},
{
"system" : "http://snomed.info/sct",
"filter" : [
{
"property" : "concept",
"op" : "is-a",
"value" : "787859002"
}
]
},
{
"valueSet" : [
"https://termgit.elga.gv.at/ValueSet/eimpf-immunizationtarget"
]
}
]
}
}