Unable to compare with previous version: Unable to find version history at https://fhir.hl7.at/elga/ediag/r4 (Problem #1 with package-list.json at https://fhir.hl7.at/elga/ediag/r4: 404 Not Found)
IPA Comparison:
n/a
IPS Comparison:
n/a
Validation Flags:
On: autoLoad, displayWarnings; Off: hintAboutNonMustSupport, anyExtensionsAllowed, checkAggregation, showReferenceMessages, noExperimentalContent
The link 'uc_ediag_02_schreiben.html#summary-liste-aktualisieren-write' for "Summary-Liste aktualisieren ($write)" cannot be resolvedHTML_LINK_CHECK_FAILED
The link 'uc_ediag_02_schreiben.html#summary-liste-aktualisieren-write' for "Summary-Liste aktualisieren ($write)" cannot be resolvedHTML_LINK_CHECK_FAILED
The link 'OperationDefinition-at-ediag-operation-list-write.html#validierung--fehlerbehandlung' for "validieren" cannot be resolvedHTML_LINK_CHECK_FAILED
HL7 Defined CodeSystems should ensure that every concept has a definitionCODESYSTEM_CONCEPT_NO_DEFINITION
--
Resource
warning
The resource CodeSystem/at-ediag-codesystem-reaction-time-cs should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
Wrong Display Name 'Gerät' for http://snomed.info/sct#49062001. Valid display is one of 3 choices: 'Device' (en), 'Device, NOS' (en) or 'Device (physical object)' (en) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
0ms tx-op
0ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: Validate "[http://snomed.info/sct#49062001 ("Gerät")]"
0ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: Check "http://snomed.info/sct#49062001"
0ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: CodeSystem found: http://snomed.info/sct|http://snomed.info/sct/900000000000207008/version/20250201 for http://snomed.info/sct|http://snomed.info/sct/900000000000207008/version/20250201
0ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: check code in (http://snomed.info/sct) at CodeableConcept.coding[0]
0ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: Code "49062001" found in http://snomed.info/sct|http://snomed.info/sct/900000000000207008/version/20250201
ImplementationGuide/hl7.at.fhir.elga.ediag.r4: ImplementationGuide: Validated against fhir.ImplementationGuide
Path
Severity
Message
Validating
Resource
information
The resource ImplementationGuide/hl7.at.fhir.elga.ediag.r4 could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
The resource OperationDefinition/at-ediag-operation-diagnose-delete could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
The resource OperationDefinition/at-ediag-operation-diagnose-entered-in-error could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
The resource OperationDefinition/at-ediag-operation-list-delete-history-version could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
The resource OperationDefinition/at-ediag-operation-list-write could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
A definition for CodeSystem 'https://termgit.elga.gv.at/CodeSystem/hl7-at-religionaustria' could not be found, so the code cannot be validated (from https://tx.fhir.org/r4) UNKNOWN_CODESYSTEM
A definition for CodeSystem 'https://termgit.elga.gv.at/CodeSystem/iso-3166-1-alpha-3' could not be found, so the code cannot be validated (from https://tx.fhir.org/r4) UNKNOWN_CODESYSTEM
The extension http://hl7.org/fhir/StructureDefinition/elementdefinition-maxValueSet|5.3.0 is deprecated with the note: 'Use additionalBinding extension or element instead'MSG_DEPENDS_ON_DEPRECATED_NOTE
The resource StructureDefinition/at-elga-ediag-allergyintolerance could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
The resource StructureDefinition/at-elga-ediag-condition could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
The element https://fhir.hl7.at/elga/ediag/r4/StructureDefinition/at-elga-ediag-condition#Condition is not validSD_CONTEXT_SHOULD_ELEMENT_NOT_FOUND
--
StructureDefinition.context[1]
error
The element https://fhir.hl7.at/elga/ediag/r4/StructureDefinition/at-elga-ediag-procedure#Procedure is not validSD_CONTEXT_SHOULD_ELEMENT_NOT_FOUND
--
StructureDefinition.context[2]
error
The element https://fhir.hl7.at/elga/ediag/r4/StructureDefinition/at-elga-ediag-allergyintolerance#AllergyIntolerance is not validSD_CONTEXT_SHOULD_ELEMENT_NOT_FOUND
--
Resource
information
The resource StructureDefinition/at-elga-ediag-ext-entered-in-error could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
The definition for the element 'List.code' binds to the value set 'https://fhir.hl7.at/elga/ediag/r4/ValueSet/at-ediag-list-code-vs' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
The definition for the element 'List.emptyReason' binds to the value set 'https://fhir.hl7.at/elga/ediag/r4/ValueSet/at-ediag-list-emptyreason-vs' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
The definition for the element 'List.code' binds to the value set 'https://fhir.hl7.at/elga/ediag/r4/ValueSet/at-ediag-list-code-vs' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
The definition for the element 'List.emptyReason' binds to the value set 'https://fhir.hl7.at/elga/ediag/r4/ValueSet/at-ediag-list-emptyreason-vs' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
--
Resource
information
The resource StructureDefinition/at-elga-ediag-list could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
The definition for the element 'Procedure.status' binds to the value set 'https://fhir.hl7.at/elga/ediag/r4/ValueSet/at-ediag-procedure-status' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
The definition for the element 'Procedure.code' binds to the value set 'https://fhir.hl7.at/elga/ediag/r4/ValueSet/at-ediag-prozeduren-codes' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
The definition for the element 'Procedure.status' binds to the value set 'https://fhir.hl7.at/elga/ediag/r4/ValueSet/at-ediag-procedure-status' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
The definition for the element 'Procedure.code' binds to the value set 'https://fhir.hl7.at/elga/ediag/r4/ValueSet/at-ediag-prozeduren-codes' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
--
Resource
information
The resource StructureDefinition/at-elga-ediag-procedure could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
The resource StructureDefinition/at-elga-ediag-reaction-time could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
Review the extension type for at-elga-ediag-reported: extensions should not have a context of Element unless it's really intended that they can be used anywhereSD_CONTEXT_SHOULD_NOT_BE_ELEMENT
--
Resource
information
The resource StructureDefinition/at-elga-ediag-reported could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
The resource ValueSet/at-ediag-allergyintolerance-codes should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
The resource ValueSet/at-ediag-diagnosen-codes should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
The resource ValueSet/at-ediag-list-code-vs should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
The resource ValueSet/at-ediag-list-emptyreason-vs should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
Reference to draft CodeSystem http://hl7.org/fhir/event-status|4.0.1MSG_DRAFT
--
Resource
warning
The resource ValueSet/at-ediag-procedure-status should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
The resource ValueSet/at-ediag-prozeduren-codes should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
The resource ValueSet/at-ediag-reaction-time-vs should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
Wrong Display Name 'Gerät' for http://snomed.info/sct#49062001. Valid display is one of 3 choices: 'Device' (en), 'Device, NOS' (en) or 'Device (physical object)' (en) (for the language(s) 'en-US')
The extension http://hl7.org/fhir/StructureDefinition/elementdefinition-maxValueSet|5.3.0 is deprecated with the note: 'Use additionalBinding extension or element instead'
Review the extension type for at-elga-ediag-reported: extensions should not have a context of Element unless it's really intended that they can be used anywhere
The definition for the element 'List.code' binds to the value set 'https://fhir.hl7.at/elga/ediag/r4/ValueSet/at-ediag-list-code-vs' which is experimental, but this structure is not labeled as experimental
The definition for the element 'List.emptyReason' binds to the value set 'https://fhir.hl7.at/elga/ediag/r4/ValueSet/at-ediag-list-emptyreason-vs' which is experimental, but this structure is not labeled as experimental
The definition for the element 'List.code' binds to the value set 'https://fhir.hl7.at/elga/ediag/r4/ValueSet/at-ediag-list-code-vs' which is experimental, but this structure is not labeled as experimental
The definition for the element 'List.emptyReason' binds to the value set 'https://fhir.hl7.at/elga/ediag/r4/ValueSet/at-ediag-list-emptyreason-vs' which is experimental, but this structure is not labeled as experimental
The definition for the element 'Procedure.status' binds to the value set 'https://fhir.hl7.at/elga/ediag/r4/ValueSet/at-ediag-procedure-status' which is experimental, but this structure is not labeled as experimental
The definition for the element 'Procedure.code' binds to the value set 'https://fhir.hl7.at/elga/ediag/r4/ValueSet/at-ediag-prozeduren-codes' which is experimental, but this structure is not labeled as experimental
The definition for the element 'Procedure.status' binds to the value set 'https://fhir.hl7.at/elga/ediag/r4/ValueSet/at-ediag-procedure-status' which is experimental, but this structure is not labeled as experimental
The definition for the element 'Procedure.code' binds to the value set 'https://fhir.hl7.at/elga/ediag/r4/ValueSet/at-ediag-prozeduren-codes' which is experimental, but this structure is not labeled as experimental