Validation Results for EUAITransparencyIG

Generated Fri Jul 31 11:09:08 UTC 2026, FHIR version 5.0.0 for fhir.ig.eu.aitransparency#0.1.0 (canonical = http://example.org/fhir/eu-ai-transparency (history)). See Errors Only & IP

Quality Checks
Publisher Version:IG Publisher Version: v2.2.11
Publication Code:n/a . PackageId = fhir.ig.eu.aitransparency, Canonical = http://example.org/fhir/eu-ai-transparency
Realm Check for n/a:
  • n/a
Language Info:Stated Languages: n/a. IG Resource Lang: en. 1 of 101 (0%) of resources have a language. Population Policy: NONE
Publication Request:
  • This IG has never been published
  • No publication request found
Supressed Messages:No Suppressed Issues
Dependency Checks:
PackageVersionFHIRCanonicalWeb BaseComment
.. fhir.ig.eu.aitransparency0.1.0R5http://example.org/fhir/eu-ai-transparency
... hl7.terminology.r57.3.0 MR5http://terminology.hl7.orghttp://terminology.hl7.org/7.3.0
.... hl7.fhir.uv.extensions.r55.3.0 MR5http://hl7.org/fhir/extensionshttp://hl7.org/fhir/extensions/5.3.0
..... hl7.terminology.r57.1.0 OR5http://terminology.hl7.orghttp://terminology.hl7.org/7.1.0Latest Release is 7.3.0
...... hl7.fhir.uv.extensions.r55.2.0 OR5http://hl7.org/fhir/extensionshttp://hl7.org/fhir/extensions/5.2.0Latest Release is 5.3.0
... hl7.fhir.uv.extensions.r55.3.0 MR5http://hl7.org/fhir/extensionshttp://hl7.org/fhir/extensions/5.3.0 (as above)
... hl7.fhir.uv.tools.r51.1.2 MR5http://hl7.org/fhir/toolshttp://hl7.org/fhir/tools/1.1.2Internal Dependency
Templates: fhir.base.template#current
Related IGs:n/a
Dependent IGs:no references
Global Profiles:(none declared)
Terminology Server(s):http://tx.fhir.org/r5, https://tx.fhir.org/r5 (details)
HTA Analysis:Non-HL7 Igs are exempt from terminology dependency analysis
R5 Dependencies:(none)
Draft Dependencies:
Modifier Extensions:(none)
Previous Version Comparison: Unable to compare with previous version: Unable to find version history at http://example.org/fhir/eu-ai-transparency (Problem #1 with package-list.json at http://example.org/fhir/eu-ai-transparency: Not Found)
IPA Comparison: n/a
IPS Comparison: n/a
Validation Flags: On: autoLoad; Off: hintAboutNonMustSupport, anyExtensionsAllowed, checkAggregation, showReferenceMessages, noExperimentalContent, displayWarnings
Summary: errors = 0, warn = 44, info = 52, broken links = 0, pinned = n/a.
FilenameErrorsWarningsHints
Build Errors030
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/includes/fsh-link-references000
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/includes/menu000
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/ArtifactAssessment-sc-02-validation-human-oversight-001000
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/ArtifactAssessment-sc-03-override-human-oversight-001000
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/ArtifactAssessment-sc-04-correction-exp-human-oversight-001000
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/AuditEvent-sc-01-ai-only-audit-event-ai-execution-001001
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/AuditEvent-sc-02-validation-audit-event-ai-execution-001001
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/AuditEvent-sc-03-override-audit-event-ai-execution-001001
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/AuditEvent-sc-04-correction-exp-audit-event-ai-execution-001001
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/CodeSystem-ehds-data-category-cs010
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/CodeSystem-ehds-secondary-use-purpose-cs010
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/CodeSystem-ehds-usage-category-cs010
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/CodeSystem-eu-ai-artifact-type-cs010
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/CodeSystem-eu-ai-audit-entity-role020
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/CodeSystem-eu-ai-case-specific-indication-cs010
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/CodeSystem-eu-ai-clinical-validation-status-cs010
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/CodeSystem-eu-ai-contact-purpose-cs010
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/CodeSystem-eu-ai-data-quality-cs010
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/CodeSystem-eu-ai-human-oversight-cs010
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/CodeSystem-eu-ai-identifier-type-cs010
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/CodeSystem-eu-ai-involvement-cs010
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/CodeSystem-eu-ai-performance-metric-cs010
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/CodeSystem-eu-ai-system-property-cs010
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/CodeSystem-gdpr-art6-codesystem010
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/CodeSystem-gdpr-art9-codesystem010
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/Communication-sc-04-correction-exp-patient-explanation-001000
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/Device-device-riskassist-ai000
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/DocumentReference-modelcard-riskassist-ai001
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/Encounter-encounter-001000
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/ImplementationGuide-fhir.ig.eu.aitransparency0016
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/Observation-sc-01-ai-only-ai-observation-risk-001000
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/Observation-sc-01-ai-only-observation-blood-pressure-001000
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/Observation-sc-01-ai-only-observation-consciousness-status-001000
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/Observation-sc-01-ai-only-observation-heart-rate-001000
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/Observation-sc-01-ai-only-observation-oxygen-saturation-001000
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/Observation-sc-01-ai-only-observation-respiratory-rate-001000
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/Observation-sc-01-ai-only-observation-temperature-001000
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/Observation-sc-02-validation-ai-observation-risk-001000
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/Observation-sc-02-validation-observation-blood-pressure-001000
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/Observation-sc-02-validation-observation-consciousness-status-001000
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/Observation-sc-02-validation-observation-heart-rate-001000
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/Observation-sc-02-validation-observation-oxygen-saturation-001000
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/Observation-sc-02-validation-observation-respiratory-rate-001000
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/Observation-sc-02-validation-observation-temperature-001000
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/Observation-sc-03-override-ai-observation-risk-001000
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/Observation-sc-03-override-observation-blood-pressure-001000
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/Observation-sc-03-override-observation-consciousness-status-001000
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/Observation-sc-03-override-observation-heart-rate-001000
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/Observation-sc-03-override-observation-oxygen-saturation-001000
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/Observation-sc-03-override-observation-respiratory-rate-001000
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/Observation-sc-03-override-observation-temperature-001000
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/Observation-sc-04-correction-exp-ai-observation-risk-001000
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/Observation-sc-04-correction-exp-corrected-clinical-observation-001000
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/Observation-sc-04-correction-exp-observation-blood-pressure-001000
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/Observation-sc-04-correction-exp-observation-consciousness-status-001000
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/Observation-sc-04-correction-exp-observation-heart-rate-001000
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/Observation-sc-04-correction-exp-observation-oxygen-saturation-001000
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/Observation-sc-04-correction-exp-observation-respiratory-rate-001000
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/Observation-sc-04-correction-exp-observation-temperature-001000
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/Organization-organization-examplehospital002
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/Organization-organization-examplemed002
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/Patient-patient-001000
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/Practitioner-practitioner-001000
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/PractitionerRole-practitionerrole-reviewer-001000
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/Provenance-example-secondary-use-provenance000
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/Provenance-sc-01-ai-only-provenance-ai-output-001000
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/Provenance-sc-02-validation-provenance-ai-output-001000
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/Provenance-sc-03-override-provenance-ai-output-001000
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/Provenance-sc-04-correction-exp-provenance-ai-output-001000
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/StructureDefinition-ai-clinical-validation-status001
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/StructureDefinition-ai-performance-metrics001
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/StructureDefinition-ai-retention-information001
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/StructureDefinition-ai-system-training-status001
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/StructureDefinition-ai-training-data001
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/StructureDefinition-automated-decision-flag001
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/StructureDefinition-case-specific-indication001
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/StructureDefinition-ehds-data-permit001
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/StructureDefinition-ehds-secondary-use-purpose001
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/StructureDefinition-ehds-usage-category001
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/StructureDefinition-eu-ai-device011
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/StructureDefinition-eu-ai-human-oversight031
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/StructureDefinition-eu-ai-log-integrity011
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/StructureDefinition-eu-ai-machine-execution-audit-event015
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/StructureDefinition-eu-ai-model-card001
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/StructureDefinition-eu-ai-observation022
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/StructureDefinition-eu-ai-organization001
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/StructureDefinition-eu-ai-patient-explanation021
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/StructureDefinition-eu-ai-practitionerrole011
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/StructureDefinition-eu-ai-provenance001
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/StructureDefinition-ext-model-card001
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/StructureDefinition-third-country-data-transfer001
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/ValueSet-ehds-data-category-vs010
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/ValueSet-ehds-secondary-use-purpose-vs010
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/ValueSet-ehds-usage-category-vs010
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/ValueSet-eu-ai-audit-entity-role-vs020
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/ValueSet-eu-ai-case-specific-indication-vs010
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/ValueSet-eu-ai-clinical-validation-status-vs010
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/ValueSet-eu-ai-data-quality-vs010
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/ValueSet-eu-ai-human-oversight-action-vs010
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/ValueSet-eu-ai-involvement-vs010
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/ValueSet-eu-ai-performance-metric-vs010
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/ValueSet-gdpr-art6-legal-basis-vs010
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/fsh-generated/resources/ValueSet-gdpr-art9-condition-vs010
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/input/pagecontent/dependencies000
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/input/pagecontent/examples000
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/input/pagecontent/extensions000
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/input/pagecontent/index000
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/input/pagecontent/ip-statements000
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/input/pagecontent/profiles000
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/input/pagecontent/terminology000
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/temp/pages/_includes/artifacts000
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/template/config000
/home/runner/work/AIST-TrustworthyAI-R5/AIST-TrustworthyAI-R5/template/config/_config000

n/a Show Validation Information

1warningThe HTML fragment 'ip-statements.xhtml' is not included anywhere in the produced implementation guide
3warningAn HTML fragment from the set [dependency-table.xhtml, dependency-table-short.xhtml, dependency-table-nontech.xhtml] is not included anywhere in the produced implementation guide
4warningThe HTML fragment 'globals-table.xhtml' is not included anywhere in the produced implementation guide

fsh-generated/includes/fsh-link-references.md Show Validation Information (0)


fsh-generated/includes/menu.xml Show Validation Information (0)


fsh-generated/resources/ArtifactAssessment-sc-02-validation-human-oversight-001.json Show Validation Information (1)


fsh-generated/resources/ArtifactAssessment-sc-03-override-human-oversight-001.json Show Validation Information (1)


fsh-generated/resources/ArtifactAssessment-sc-04-correction-exp-human-oversight-001.json Show Validation Information (1)


fsh-generated/resources/AuditEvent-sc-01-ai-only-audit-event-ai-execution-001.json Show Validation Information (1)

PathSeverityMessageValidating
AuditEvent.entity[0].role (l63/c8)informationReference to draft CodeSystem http://example.org/fhir/eu-ai-transparency/CodeSystem/eu-ai-audit-entity-role|0.1.0 MSG_DRAFTEU AI Execution Audit Event

fsh-generated/resources/AuditEvent-sc-02-validation-audit-event-ai-execution-001.json Show Validation Information (1)

PathSeverityMessageValidating
AuditEvent.entity[0].role (l63/c8)informationReference to draft CodeSystem http://example.org/fhir/eu-ai-transparency/CodeSystem/eu-ai-audit-entity-role|0.1.0 MSG_DRAFTEU AI Execution Audit Event

fsh-generated/resources/AuditEvent-sc-03-override-audit-event-ai-execution-001.json Show Validation Information (1)

PathSeverityMessageValidating
AuditEvent.entity[0].role (l63/c8)informationReference to draft CodeSystem http://example.org/fhir/eu-ai-transparency/CodeSystem/eu-ai-audit-entity-role|0.1.0 MSG_DRAFTEU AI Execution Audit Event

fsh-generated/resources/AuditEvent-sc-04-correction-exp-audit-event-ai-execution-001.json Show Validation Information (1)

PathSeverityMessageValidating
AuditEvent.entity[0].role (l63/c8)informationReference to draft CodeSystem http://example.org/fhir/eu-ai-transparency/CodeSystem/eu-ai-audit-entity-role|0.1.0 MSG_DRAFTEU AI Execution Audit Event

fsh-generated/resources/CodeSystem-ehds-data-category-cs.json Show Validation Information (1)

PathSeverityMessageValidating
ResourcewarningThe resource CodeSystem/ehds-data-category-cs should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/CodeSystem-ehds-secondary-use-purpose-cs.json Show Validation Information (1)

PathSeverityMessageValidating
ResourcewarningThe resource CodeSystem/ehds-secondary-use-purpose-cs should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/CodeSystem-ehds-usage-category-cs.json Show Validation Information (1)

PathSeverityMessageValidating
ResourcewarningThe resource CodeSystem/ehds-usage-category-cs should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/CodeSystem-eu-ai-artifact-type-cs.json Show Validation Information (1)

PathSeverityMessageValidating
ResourcewarningThe resource CodeSystem/eu-ai-artifact-type-cs should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/CodeSystem-eu-ai-audit-entity-role.json Show Validation Information (1)

PathSeverityMessageValidating
CodeSystem (l1/c1742)warningPublished code systems SHOULD conform to the ShareableCodeSystem profile, which says that the element CodeSystem.experimental is mandatory, but it is not present CODESYSTEM_SHAREABLE_MISSING--
ResourcewarningThe resource CodeSystem/eu-ai-audit-entity-role should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/CodeSystem-eu-ai-case-specific-indication-cs.json Show Validation Information (1)

PathSeverityMessageValidating
ResourcewarningThe resource CodeSystem/eu-ai-case-specific-indication-cs should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/CodeSystem-eu-ai-clinical-validation-status-cs.json Show Validation Information (1)

PathSeverityMessageValidating
ResourcewarningThe resource CodeSystem/eu-ai-clinical-validation-status-cs should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/CodeSystem-eu-ai-contact-purpose-cs.json Show Validation Information (1)

PathSeverityMessageValidating
ResourcewarningThe resource CodeSystem/eu-ai-contact-purpose-cs should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/CodeSystem-eu-ai-data-quality-cs.json Show Validation Information (1)

PathSeverityMessageValidating
ResourcewarningThe resource CodeSystem/eu-ai-data-quality-cs should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/CodeSystem-eu-ai-human-oversight-cs.json Show Validation Information (1)

PathSeverityMessageValidating
ResourcewarningThe resource CodeSystem/eu-ai-human-oversight-cs should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/CodeSystem-eu-ai-identifier-type-cs.json Show Validation Information (1)

PathSeverityMessageValidating
ResourcewarningThe resource CodeSystem/eu-ai-identifier-type-cs should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/CodeSystem-eu-ai-involvement-cs.json Show Validation Information (1)

PathSeverityMessageValidating
ResourcewarningThe resource CodeSystem/eu-ai-involvement-cs should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/CodeSystem-eu-ai-performance-metric-cs.json Show Validation Information (1)

PathSeverityMessageValidating
ResourcewarningThe resource CodeSystem/eu-ai-performance-metric-cs should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/CodeSystem-eu-ai-system-property-cs.json Show Validation Information (1)

PathSeverityMessageValidating
ResourcewarningThe resource CodeSystem/eu-ai-system-property-cs should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/CodeSystem-gdpr-art6-codesystem.json Show Validation Information (1)

PathSeverityMessageValidating
ResourcewarningThe resource CodeSystem/gdpr-art6-codesystem should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/CodeSystem-gdpr-art9-codesystem.json Show Validation Information (1)

PathSeverityMessageValidating
ResourcewarningThe resource CodeSystem/gdpr-art9-codesystem should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/Communication-sc-04-correction-exp-patient-explanation-001.json Show Validation Information (1)


fsh-generated/resources/Device-device-riskassist-ai.json Show Validation Information (1)


fsh-generated/resources/DocumentReference-modelcard-riskassist-ai.json Show Validation Information (1)

PathSeverityMessageValidating
DocumentReference.type (l120/c4)informationNone of the codings provided are in the value set 'FHIR Document Type Codes' (http://hl7.org/fhir/ValueSet/doc-typecodes|5.0.0), and a coding is recommended to come from this value set (codes = http://example.org/fhir/eu-ai-transparency/CodeSystem/eu-ai-artifact-type-cs#model-card) Terminology_TX_NoValid_3_CCEU AI Act Model Card

fsh-generated/resources/Encounter-encounter-001.json Show Validation Information (1)


fsh-generated/resources/ImplementationGuide-fhir.ig.eu.aitransparency.json Show Validation Information (1)

PathSeverityMessageValidating
ImplementationGuide​.definition​.parameter[3]​.code (l1​/c42652)informationReference to experimental CodeSystem http://hl7.org/fhir/guide-parameter-code|5.0.0 MSG_EXPERIMENTALImplementationGuide
ImplementationGuide​.definition​.parameter[4]​.code (l1​/c42767)informationReference to experimental CodeSystem http://hl7.org/fhir/guide-parameter-code|5.0.0 MSG_EXPERIMENTALImplementationGuide
ImplementationGuide​.definition​.parameter[5]​.code (l1​/c42878)informationReference to experimental CodeSystem http://hl7.org/fhir/guide-parameter-code|5.0.0 MSG_EXPERIMENTALImplementationGuide
ImplementationGuide​.definition​.parameter[6]​.code (l1​/c42991)informationReference to experimental CodeSystem http://hl7.org/fhir/guide-parameter-code|5.0.0 MSG_EXPERIMENTALImplementationGuide
ImplementationGuide​.definition​.parameter[7]​.code (l1​/c43100)informationReference to experimental CodeSystem http://hl7.org/fhir/guide-parameter-code|5.0.0 MSG_EXPERIMENTALImplementationGuide
ImplementationGuide​.definition​.parameter[8]​.code (l1​/c43213)informationReference to experimental CodeSystem http://hl7.org/fhir/guide-parameter-code|5.0.0 MSG_EXPERIMENTALImplementationGuide
ImplementationGuide​.definition​.parameter[9]​.code (l1​/c43324)informationReference to experimental CodeSystem http://hl7.org/fhir/guide-parameter-code|5.0.0 MSG_EXPERIMENTALImplementationGuide
ImplementationGuide​.definition​.parameter[10]​.code (l1​/c43436)informationReference to experimental CodeSystem http://hl7.org/fhir/guide-parameter-code|5.0.0 MSG_EXPERIMENTALImplementationGuide
ImplementationGuide​.definition​.parameter[11]​.code (l1​/c43549)informationReference to experimental CodeSystem http://hl7.org/fhir/guide-parameter-code|5.0.0 MSG_EXPERIMENTALImplementationGuide
ImplementationGuide​.definition​.parameter[12]​.code (l1​/c43656)informationReference to experimental CodeSystem http://hl7.org/fhir/guide-parameter-code|5.0.0 MSG_EXPERIMENTALImplementationGuide
ImplementationGuide​.definition​.parameter[13]​.code (l1​/c43766)informationReference to experimental CodeSystem http://hl7.org/fhir/guide-parameter-code|5.0.0 MSG_EXPERIMENTALImplementationGuide
ImplementationGuide​.definition​.parameter[14]​.code (l1​/c43876)informationReference to experimental CodeSystem http://hl7.org/fhir/guide-parameter-code|5.0.0 MSG_EXPERIMENTALImplementationGuide
ImplementationGuide​.definition​.parameter[15]​.code (l1​/c43993)informationReference to experimental CodeSystem http://hl7.org/fhir/guide-parameter-code|5.0.0 MSG_EXPERIMENTALImplementationGuide
ImplementationGuide​.definition​.parameter[16]​.code (l1​/c44102)informationReference to experimental CodeSystem http://hl7.org/fhir/guide-parameter-code|5.0.0 MSG_EXPERIMENTALImplementationGuide
ImplementationGuide​.definition​.parameter[22]​.code (l1​/c44780)informationReference to experimental CodeSystem http://hl7.org/fhir/guide-parameter-code|5.0.0 MSG_EXPERIMENTALImplementationGuide
ResourceinformationThe resource ImplementationGuide/fhir.ig.eu.aitransparency could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/Observation-sc-01-ai-only-ai-observation-risk-001.json Show Validation Information (1)


fsh-generated/resources/Observation-sc-01-ai-only-observation-blood-pressure-001.json Show Validation Information (1)


fsh-generated/resources/Observation-sc-01-ai-only-observation-consciousness-status-001.json Show Validation Information (1)


fsh-generated/resources/Observation-sc-01-ai-only-observation-heart-rate-001.json Show Validation Information (1)


fsh-generated/resources/Observation-sc-01-ai-only-observation-oxygen-saturation-001.json Show Validation Information (1)


fsh-generated/resources/Observation-sc-01-ai-only-observation-respiratory-rate-001.json Show Validation Information (1)


fsh-generated/resources/Observation-sc-01-ai-only-observation-temperature-001.json Show Validation Information (1)


fsh-generated/resources/Observation-sc-02-validation-ai-observation-risk-001.json Show Validation Information (1)


fsh-generated/resources/Observation-sc-02-validation-observation-blood-pressure-001.json Show Validation Information (1)


fsh-generated/resources/Observation-sc-02-validation-observation-consciousness-status-001.json Show Validation Information (1)


fsh-generated/resources/Observation-sc-02-validation-observation-heart-rate-001.json Show Validation Information (1)


fsh-generated/resources/Observation-sc-02-validation-observation-oxygen-saturation-001.json Show Validation Information (1)


fsh-generated/resources/Observation-sc-02-validation-observation-respiratory-rate-001.json Show Validation Information (1)


fsh-generated/resources/Observation-sc-02-validation-observation-temperature-001.json Show Validation Information (1)


fsh-generated/resources/Observation-sc-03-override-ai-observation-risk-001.json Show Validation Information (1)


fsh-generated/resources/Observation-sc-03-override-observation-blood-pressure-001.json Show Validation Information (1)


fsh-generated/resources/Observation-sc-03-override-observation-consciousness-status-001.json Show Validation Information (1)


fsh-generated/resources/Observation-sc-03-override-observation-heart-rate-001.json Show Validation Information (1)


fsh-generated/resources/Observation-sc-03-override-observation-oxygen-saturation-001.json Show Validation Information (1)


fsh-generated/resources/Observation-sc-03-override-observation-respiratory-rate-001.json Show Validation Information (1)


fsh-generated/resources/Observation-sc-03-override-observation-temperature-001.json Show Validation Information (1)


fsh-generated/resources/Observation-sc-04-correction-exp-ai-observation-risk-001.json Show Validation Information (1)


fsh-generated/resources/Observation-sc-04-correction-exp-corrected-clinical-observation-001.json Show Validation Information (1)


fsh-generated/resources/Observation-sc-04-correction-exp-observation-blood-pressure-001.json Show Validation Information (1)


fsh-generated/resources/Observation-sc-04-correction-exp-observation-consciousness-status-001.json Show Validation Information (1)


fsh-generated/resources/Observation-sc-04-correction-exp-observation-heart-rate-001.json Show Validation Information (1)


fsh-generated/resources/Observation-sc-04-correction-exp-observation-oxygen-saturation-001.json Show Validation Information (1)


fsh-generated/resources/Observation-sc-04-correction-exp-observation-respiratory-rate-001.json Show Validation Information (1)


fsh-generated/resources/Observation-sc-04-correction-exp-observation-temperature-001.json Show Validation Information (1)


fsh-generated/resources/Organization-organization-examplehospital.json Show Validation Information (1)

PathSeverityMessageValidating
Organization​.contact[1]​.purpose (l45​/c8)informationNone of the codings provided are in the value set 'Contact entity type' (http://terminology.hl7.org/ValueSet/contactentity-type|2.0.0), and a coding is recommended to come from this value set (codes = http://example.org/fhir/eu-ai-transparency/CodeSystem/eu-ai-contact-purpose-cs#dpo) Terminology_TX_NoValid_3_CCEU AI Responsible Organization
Organization​.contact[2]​.purpose (l68​/c8)informationNone of the codings provided are in the value set 'Contact entity type' (http://terminology.hl7.org/ValueSet/contactentity-type|2.0.0), and a coding is recommended to come from this value set (codes = http://example.org/fhir/eu-ai-transparency/CodeSystem/eu-ai-contact-purpose-cs#ai-incident-reporting) Terminology_TX_NoValid_3_CCEU AI Responsible Organization

fsh-generated/resources/Organization-organization-examplemed.json Show Validation Information (1)

PathSeverityMessageValidating
Organization​.contact[1]​.purpose (l45​/c8)informationNone of the codings provided are in the value set 'Contact entity type' (http://terminology.hl7.org/ValueSet/contactentity-type|2.0.0), and a coding is recommended to come from this value set (codes = http://example.org/fhir/eu-ai-transparency/CodeSystem/eu-ai-contact-purpose-cs#dpo) Terminology_TX_NoValid_3_CCEU AI Responsible Organization
Organization​.contact[2]​.purpose (l68​/c8)informationNone of the codings provided are in the value set 'Contact entity type' (http://terminology.hl7.org/ValueSet/contactentity-type|2.0.0), and a coding is recommended to come from this value set (codes = http://example.org/fhir/eu-ai-transparency/CodeSystem/eu-ai-contact-purpose-cs#ai-incident-reporting) Terminology_TX_NoValid_3_CCEU AI Responsible Organization

fsh-generated/resources/Patient-patient-001.json Show Validation Information (1)


fsh-generated/resources/Practitioner-practitioner-001.json Show Validation Information (1)


fsh-generated/resources/PractitionerRole-practitionerrole-reviewer-001.json Show Validation Information (1)


fsh-generated/resources/Provenance-example-secondary-use-provenance.json Show Validation Information (1)


fsh-generated/resources/Provenance-sc-01-ai-only-provenance-ai-output-001.json Show Validation Information (1)


fsh-generated/resources/Provenance-sc-02-validation-provenance-ai-output-001.json Show Validation Information (1)


fsh-generated/resources/Provenance-sc-03-override-provenance-ai-output-001.json Show Validation Information (1)


fsh-generated/resources/Provenance-sc-04-correction-exp-provenance-ai-output-001.json Show Validation Information (1)


fsh-generated/resources/StructureDefinition-ai-clinical-validation-status.json Show Validation Information (1)

PathSeverityMessageValidating
ResourceinformationThe resource StructureDefinition/ai-clinical-validation-status could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/StructureDefinition-ai-performance-metrics.json Show Validation Information (1)

PathSeverityMessageValidating
ResourceinformationThe resource StructureDefinition/ai-performance-metrics could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/StructureDefinition-ai-retention-information.json Show Validation Information (1)

PathSeverityMessageValidating
ResourceinformationThe resource StructureDefinition/ai-retention-information could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/StructureDefinition-ai-system-training-status.json Show Validation Information (1)

PathSeverityMessageValidating
ResourceinformationThe resource StructureDefinition/ai-system-training-status could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/StructureDefinition-ai-training-data.json Show Validation Information (1)

PathSeverityMessageValidating
ResourceinformationThe resource StructureDefinition/ai-training-data could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/StructureDefinition-automated-decision-flag.json Show Validation Information (1)

PathSeverityMessageValidating
ResourceinformationThe resource StructureDefinition/automated-decision-flag could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/StructureDefinition-case-specific-indication.json Show Validation Information (1)

PathSeverityMessageValidating
ResourceinformationThe resource StructureDefinition/case-specific-indication could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/StructureDefinition-ehds-data-permit.json Show Validation Information (1)

PathSeverityMessageValidating
ResourceinformationThe resource StructureDefinition/ehds-data-permit could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/StructureDefinition-ehds-secondary-use-purpose.json Show Validation Information (1)

PathSeverityMessageValidating
ResourceinformationThe resource StructureDefinition/ehds-secondary-use-purpose could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/StructureDefinition-ehds-usage-category.json Show Validation Information (1)

PathSeverityMessageValidating
ResourceinformationThe resource StructureDefinition/ehds-usage-category could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/StructureDefinition-eu-ai-device.json Show Validation Information (1)

PathSeverityMessageValidating
StructureDefinition​.snapshot​.element[46]​.bindingwarningThe definition for the element 'Device.name.type' binds to the value set 'http://hl7.org/fhir/ValueSet/device-nametype|5.0.0' which is experimental, but this structure is not labeled as experimental SD_ED_EXPERIMENTAL_BINDING--
ResourceinformationThe resource StructureDefinition/eu-ai-device could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/StructureDefinition-eu-ai-human-oversight.json Show Validation Information (1)

PathSeverityMessageValidating
StructureDefinition​.snapshot​.element[22]​.bindingwarningThe definition for the element 'ArtifactAssessment.content.informationType' binds to the value set 'http://hl7.org/fhir/ValueSet/artifactassessment-information-type|5.0.0' which is experimental, but this structure is not labeled as experimental SD_ED_EXPERIMENTAL_BINDING--
StructureDefinition​.snapshot​.element[32]​.bindingwarningThe definition for the element 'ArtifactAssessment.workflowStatus' binds to the value set 'http://hl7.org/fhir/ValueSet/artifactassessment-workflow-status|5.0.0' which is experimental, but this structure is not labeled as experimental SD_ED_EXPERIMENTAL_BINDING--
StructureDefinition​.snapshot​.element[33]​.bindingwarningThe definition for the element 'ArtifactAssessment.disposition' binds to the value set 'http://hl7.org/fhir/ValueSet/artifactassessment-disposition|5.0.0' which is experimental, but this structure is not labeled as experimental SD_ED_EXPERIMENTAL_BINDING--
ResourceinformationThe resource StructureDefinition/eu-ai-human-oversight could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/StructureDefinition-eu-ai-log-integrity.json Show Validation Information (1)

PathSeverityMessageValidating
StructureDefinition​.snapshot​.element[7]​.bindingwarningThe definition for the element 'Extension.value[x].type' binds to the value set 'http://hl7.org/fhir/ValueSet/signature-type|5.0.0' which is experimental, but this structure is not labeled as experimental SD_ED_EXPERIMENTAL_BINDING--
ResourceinformationThe resource StructureDefinition/eu-ai-log-integrity could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/StructureDefinition-eu-ai-machine-execution-audit-event.json Show Validation Information (1)

PathSeverityMessageValidating
StructureDefinition​.snapshot​.element[69]​.pattern​.ofType(CodeableConcept) (l1​/c149582)informationReference to draft CodeSystem http://example.org/fhir/eu-ai-transparency/CodeSystem/eu-ai-audit-entity-role|0.1.0 MSG_DRAFTStructureDefinition
StructureDefinition​.snapshot​.element[84]​.pattern​.ofType(CodeableConcept) (l1​/c170735)informationReference to draft CodeSystem http://example.org/fhir/eu-ai-transparency/CodeSystem/eu-ai-audit-entity-role|0.1.0 MSG_DRAFTStructureDefinition
StructureDefinition​.differential​.element[14]​.pattern​.ofType(CodeableConcept) (l1​/c186289)informationReference to draft CodeSystem http://example.org/fhir/eu-ai-transparency/CodeSystem/eu-ai-audit-entity-role|0.1.0 MSG_DRAFTStructureDefinition
StructureDefinition​.differential​.element[17]​.pattern​.ofType(CodeableConcept) (l1​/c186835)informationReference to draft CodeSystem http://example.org/fhir/eu-ai-transparency/CodeSystem/eu-ai-audit-entity-role|0.1.0 MSG_DRAFTStructureDefinition
StructureDefinition​.snapshot​.element[34]​.bindingwarningThe definition for the element 'AuditEvent.agent.type' binds to the value set 'http://hl7.org/fhir/ValueSet/participation-role-type|5.0.0' which is experimental, but this structure is not labeled as experimental SD_ED_EXPERIMENTAL_BINDING--
ResourceinformationThe resource StructureDefinition/eu-ai-machine-execution-audit-event could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/StructureDefinition-eu-ai-model-card.json Show Validation Information (1)

PathSeverityMessageValidating
ResourceinformationThe resource StructureDefinition/eu-ai-model-card could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/StructureDefinition-eu-ai-observation.json Show Validation Information (1)

PathSeverityMessageValidating
StructureDefinition​.snapshot​.element[23]​.bindingwarningThe definition for the element 'Observation.category' binds to the value set 'http://hl7.org/fhir/ValueSet/observation-category|5.0.0' which is experimental, but this structure is not labeled as experimental SD_ED_EXPERIMENTAL_BINDING--
StructureDefinition​.snapshot​.element[37]​.pattern​.ofType(Coding)informationThe repeating element has a pattern. The pattern will apply to all the repeats (this has not been clear to all users) SD_VALUE_TYPE_REPEAT_HINT--
StructureDefinition​.snapshot​.element[52]​.bindingwarningThe definition for the element 'Observation.referenceRange.type' binds to the value set 'http://hl7.org/fhir/ValueSet/referencerange-meaning|5.0.0' which is experimental, but this structure is not labeled as experimental SD_ED_EXPERIMENTAL_BINDING--
ResourceinformationThe resource StructureDefinition/eu-ai-observation could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/StructureDefinition-eu-ai-organization.json Show Validation Information (1)

PathSeverityMessageValidating
ResourceinformationThe resource StructureDefinition/eu-ai-organization could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/StructureDefinition-eu-ai-patient-explanation.json Show Validation Information (1)

PathSeverityMessageValidating
StructureDefinition​.snapshot​.element[15]​.bindingwarningThe definition for the element 'Communication.status' binds to the value set 'http://hl7.org/fhir/ValueSet/event-status|5.0.0' which is experimental, but this structure is not labeled as experimental SD_ED_EXPERIMENTAL_BINDING--
StructureDefinition​.snapshot​.element[18]​.bindingwarningThe definition for the element 'Communication.priority' binds to the value set 'http://hl7.org/fhir/ValueSet/request-priority|5.0.0' which is experimental, but this structure is not labeled as experimental SD_ED_EXPERIMENTAL_BINDING--
ResourceinformationThe resource StructureDefinition/eu-ai-patient-explanation could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/StructureDefinition-eu-ai-practitionerrole.json Show Validation Information (1)

PathSeverityMessageValidating
StructureDefinition​.snapshot​.element[16]​.bindingwarningThe definition for the element 'PractitionerRole.specialty' binds to the value set 'http://hl7.org/fhir/ValueSet/c80-practice-codes|5.0.0' which is experimental, but this structure is not labeled as experimental SD_ED_EXPERIMENTAL_BINDING--
ResourceinformationThe resource StructureDefinition/eu-ai-practitionerrole could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/StructureDefinition-eu-ai-provenance.json Show Validation Information (1)

PathSeverityMessageValidating
ResourceinformationThe resource StructureDefinition/eu-ai-provenance could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/StructureDefinition-ext-model-card.json Show Validation Information (1)

PathSeverityMessageValidating
ResourceinformationThe resource StructureDefinition/ext-model-card could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/StructureDefinition-third-country-data-transfer.json Show Validation Information (1)

PathSeverityMessageValidating
ResourceinformationThe resource StructureDefinition/third-country-data-transfer could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/ValueSet-ehds-data-category-vs.json Show Validation Information (1)

PathSeverityMessageValidating
ResourcewarningThe resource ValueSet/ehds-data-category-vs should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/ValueSet-ehds-secondary-use-purpose-vs.json Show Validation Information (1)

PathSeverityMessageValidating
ResourcewarningThe resource ValueSet/ehds-secondary-use-purpose-vs should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/ValueSet-ehds-usage-category-vs.json Show Validation Information (1)

PathSeverityMessageValidating
ResourcewarningThe resource ValueSet/ehds-usage-category-vs should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/ValueSet-eu-ai-audit-entity-role-vs.json Show Validation Information (1)

PathSeverityMessageValidating
ValueSet (l1/c1137)warningPublished value sets SHOULD conform to the ShareableValueSet profile, which says that the element ValueSet.experimental is mandatory, but it is not present --
ResourcewarningThe resource ValueSet/eu-ai-audit-entity-role-vs should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/ValueSet-eu-ai-case-specific-indication-vs.json Show Validation Information (1)

PathSeverityMessageValidating
ResourcewarningThe resource ValueSet/eu-ai-case-specific-indication-vs should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/ValueSet-eu-ai-clinical-validation-status-vs.json Show Validation Information (1)

PathSeverityMessageValidating
ResourcewarningThe resource ValueSet/eu-ai-clinical-validation-status-vs should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/ValueSet-eu-ai-data-quality-vs.json Show Validation Information (1)

PathSeverityMessageValidating
ResourcewarningThe resource ValueSet/eu-ai-data-quality-vs should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/ValueSet-eu-ai-human-oversight-action-vs.json Show Validation Information (1)

PathSeverityMessageValidating
ResourcewarningThe resource ValueSet/eu-ai-human-oversight-action-vs should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/ValueSet-eu-ai-involvement-vs.json Show Validation Information (1)

PathSeverityMessageValidating
ResourcewarningThe resource ValueSet/eu-ai-involvement-vs should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/ValueSet-eu-ai-performance-metric-vs.json Show Validation Information (1)

PathSeverityMessageValidating
ResourcewarningThe resource ValueSet/eu-ai-performance-metric-vs should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/ValueSet-gdpr-art6-legal-basis-vs.json Show Validation Information (1)

PathSeverityMessageValidating
ResourcewarningThe resource ValueSet/gdpr-art6-legal-basis-vs should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/ValueSet-gdpr-art9-condition-vs.json Show Validation Information (1)

PathSeverityMessageValidating
ResourcewarningThe resource ValueSet/gdpr-art9-condition-vs should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

input/pagecontent/dependencies.md Show Validation Information (0)


input/pagecontent/examples.md Show Validation Information (0)


input/pagecontent/extensions.md Show Validation Information (0)


input/pagecontent/index.md Show Validation Information (0)


input/pagecontent/ip-statements.md Show Validation Information (0)


input/pagecontent/profiles.md Show Validation Information (0)


input/pagecontent/terminology.md Show Validation Information (0)


temp/pages/_includes/artifacts.xml Show Validation Information (0)


template/config Show Validation Information (0)


template/config/_config.yml Show Validation Information (0)

Suppressed Messages (Warnings, hints, broken links)

No suppressed messsages

Errors sorted by type


CODESYSTEM_SHAREABLE_MISSING

fsh-generated/resources/CodeSystem-eu-ai-audit-entity-role.jsonPublished code systems SHOULD conform to the ShareableCodeSystem profile, which says that the element CodeSystem.experimental is mandatory, but it is not present--

MSG_DRAFT

fsh-generated/resources/AuditEvent-sc-01-ai-only-audit-event-ai-execution-001.jsonReference to draft CodeSystem http://example.org/fhir/eu-ai-transparency/CodeSystem/eu-ai-audit-entity-role|0.1.0EU AI Execution Audit Event
fsh-generated/resources/AuditEvent-sc-02-validation-audit-event-ai-execution-001.jsonReference to draft CodeSystem http://example.org/fhir/eu-ai-transparency/CodeSystem/eu-ai-audit-entity-role|0.1.0EU AI Execution Audit Event
fsh-generated/resources/AuditEvent-sc-03-override-audit-event-ai-execution-001.jsonReference to draft CodeSystem http://example.org/fhir/eu-ai-transparency/CodeSystem/eu-ai-audit-entity-role|0.1.0EU AI Execution Audit Event
fsh-generated/resources/AuditEvent-sc-04-correction-exp-audit-event-ai-execution-001.jsonReference to draft CodeSystem http://example.org/fhir/eu-ai-transparency/CodeSystem/eu-ai-audit-entity-role|0.1.0EU AI Execution Audit Event
fsh-generated/resources/StructureDefinition-eu-ai-machine-execution-audit-event.jsonReference to draft CodeSystem http://example.org/fhir/eu-ai-transparency/CodeSystem/eu-ai-audit-entity-role|0.1.0StructureDefinition
fsh-generated/resources/StructureDefinition-eu-ai-machine-execution-audit-event.jsonReference to draft CodeSystem http://example.org/fhir/eu-ai-transparency/CodeSystem/eu-ai-audit-entity-role|0.1.0StructureDefinition
fsh-generated/resources/StructureDefinition-eu-ai-machine-execution-audit-event.jsonReference to draft CodeSystem http://example.org/fhir/eu-ai-transparency/CodeSystem/eu-ai-audit-entity-role|0.1.0StructureDefinition
fsh-generated/resources/StructureDefinition-eu-ai-machine-execution-audit-event.jsonReference to draft CodeSystem http://example.org/fhir/eu-ai-transparency/CodeSystem/eu-ai-audit-entity-role|0.1.0StructureDefinition

MSG_EXPERIMENTAL

fsh-generated/resources/ImplementationGuide-fhir.ig.eu.aitransparency.jsonReference to experimental CodeSystem http://hl7.org/fhir/guide-parameter-code|5.0.0ImplementationGuide
fsh-generated/resources/ImplementationGuide-fhir.ig.eu.aitransparency.jsonReference to experimental CodeSystem http://hl7.org/fhir/guide-parameter-code|5.0.0ImplementationGuide
fsh-generated/resources/ImplementationGuide-fhir.ig.eu.aitransparency.jsonReference to experimental CodeSystem http://hl7.org/fhir/guide-parameter-code|5.0.0ImplementationGuide
fsh-generated/resources/ImplementationGuide-fhir.ig.eu.aitransparency.jsonReference to experimental CodeSystem http://hl7.org/fhir/guide-parameter-code|5.0.0ImplementationGuide
fsh-generated/resources/ImplementationGuide-fhir.ig.eu.aitransparency.jsonReference to experimental CodeSystem http://hl7.org/fhir/guide-parameter-code|5.0.0ImplementationGuide
fsh-generated/resources/ImplementationGuide-fhir.ig.eu.aitransparency.jsonReference to experimental CodeSystem http://hl7.org/fhir/guide-parameter-code|5.0.0ImplementationGuide
fsh-generated/resources/ImplementationGuide-fhir.ig.eu.aitransparency.jsonReference to experimental CodeSystem http://hl7.org/fhir/guide-parameter-code|5.0.0ImplementationGuide
fsh-generated/resources/ImplementationGuide-fhir.ig.eu.aitransparency.jsonReference to experimental CodeSystem http://hl7.org/fhir/guide-parameter-code|5.0.0ImplementationGuide
fsh-generated/resources/ImplementationGuide-fhir.ig.eu.aitransparency.jsonReference to experimental CodeSystem http://hl7.org/fhir/guide-parameter-code|5.0.0ImplementationGuide
fsh-generated/resources/ImplementationGuide-fhir.ig.eu.aitransparency.jsonReference to experimental CodeSystem http://hl7.org/fhir/guide-parameter-code|5.0.0ImplementationGuide
fsh-generated/resources/ImplementationGuide-fhir.ig.eu.aitransparency.jsonReference to experimental CodeSystem http://hl7.org/fhir/guide-parameter-code|5.0.0ImplementationGuide
fsh-generated/resources/ImplementationGuide-fhir.ig.eu.aitransparency.jsonReference to experimental CodeSystem http://hl7.org/fhir/guide-parameter-code|5.0.0ImplementationGuide
fsh-generated/resources/ImplementationGuide-fhir.ig.eu.aitransparency.jsonReference to experimental CodeSystem http://hl7.org/fhir/guide-parameter-code|5.0.0ImplementationGuide
fsh-generated/resources/ImplementationGuide-fhir.ig.eu.aitransparency.jsonReference to experimental CodeSystem http://hl7.org/fhir/guide-parameter-code|5.0.0ImplementationGuide
fsh-generated/resources/ImplementationGuide-fhir.ig.eu.aitransparency.jsonReference to experimental CodeSystem http://hl7.org/fhir/guide-parameter-code|5.0.0ImplementationGuide

SD_ED_EXPERIMENTAL_BINDING

fsh-generated/resources/StructureDefinition-eu-ai-device.jsonThe definition for the element 'Device.name.type' binds to the value set 'http://hl7.org/fhir/ValueSet/device-nametype|5.0.0' which is experimental, but this structure is not labeled as experimental--
fsh-generated/resources/StructureDefinition-eu-ai-human-oversight.jsonThe definition for the element 'ArtifactAssessment.content.informationType' binds to the value set 'http://hl7.org/fhir/ValueSet/artifactassessment-information-type|5.0.0' which is experimental, but this structure is not labeled as experimental--
fsh-generated/resources/StructureDefinition-eu-ai-human-oversight.jsonThe definition for the element 'ArtifactAssessment.workflowStatus' binds to the value set 'http://hl7.org/fhir/ValueSet/artifactassessment-workflow-status|5.0.0' which is experimental, but this structure is not labeled as experimental--
fsh-generated/resources/StructureDefinition-eu-ai-human-oversight.jsonThe definition for the element 'ArtifactAssessment.disposition' binds to the value set 'http://hl7.org/fhir/ValueSet/artifactassessment-disposition|5.0.0' which is experimental, but this structure is not labeled as experimental--
fsh-generated/resources/StructureDefinition-eu-ai-log-integrity.jsonThe definition for the element 'Extension.value[x].type' binds to the value set 'http://hl7.org/fhir/ValueSet/signature-type|5.0.0' which is experimental, but this structure is not labeled as experimental--
fsh-generated/resources/StructureDefinition-eu-ai-machine-execution-audit-event.jsonThe definition for the element 'AuditEvent.agent.type' binds to the value set 'http://hl7.org/fhir/ValueSet/participation-role-type|5.0.0' which is experimental, but this structure is not labeled as experimental--
fsh-generated/resources/StructureDefinition-eu-ai-observation.jsonThe definition for the element 'Observation.category' binds to the value set 'http://hl7.org/fhir/ValueSet/observation-category|5.0.0' which is experimental, but this structure is not labeled as experimental--
fsh-generated/resources/StructureDefinition-eu-ai-observation.jsonThe definition for the element 'Observation.referenceRange.type' binds to the value set 'http://hl7.org/fhir/ValueSet/referencerange-meaning|5.0.0' which is experimental, but this structure is not labeled as experimental--
fsh-generated/resources/StructureDefinition-eu-ai-patient-explanation.jsonThe definition for the element 'Communication.status' binds to the value set 'http://hl7.org/fhir/ValueSet/event-status|5.0.0' which is experimental, but this structure is not labeled as experimental--
fsh-generated/resources/StructureDefinition-eu-ai-patient-explanation.jsonThe definition for the element 'Communication.priority' binds to the value set 'http://hl7.org/fhir/ValueSet/request-priority|5.0.0' which is experimental, but this structure is not labeled as experimental--
fsh-generated/resources/StructureDefinition-eu-ai-practitionerrole.jsonThe definition for the element 'PractitionerRole.specialty' binds to the value set 'http://hl7.org/fhir/ValueSet/c80-practice-codes|5.0.0' which is experimental, but this structure is not labeled as experimental--

SD_VALUE_TYPE_REPEAT_HINT

fsh-generated/resources/StructureDefinition-eu-ai-observation.jsonThe repeating element has a pattern. The pattern will apply to all the repeats (this has not been clear to all users)--

Terminology_TX_NoValid_3_CC

fsh-generated/resources/DocumentReference-modelcard-riskassist-ai.jsonNone of the codings provided are in the value set 'FHIR Document Type Codes' (http://hl7.org/fhir/ValueSet/doc-typecodes|5.0.0), and a coding is recommended to come from this value set (codes = http://example.org/fhir/eu-ai-transparency/CodeSystem/eu-ai-artifact-type-cs#model-card)EU AI Act Model Card
fsh-generated/resources/Organization-organization-examplehospital.jsonNone of the codings provided are in the value set 'Contact entity type' (http://terminology.hl7.org/ValueSet/contactentity-type|2.0.0), and a coding is recommended to come from this value set (codes = http://example.org/fhir/eu-ai-transparency/CodeSystem/eu-ai-contact-purpose-cs#dpo)EU AI Responsible Organization
fsh-generated/resources/Organization-organization-examplehospital.jsonNone of the codings provided are in the value set 'Contact entity type' (http://terminology.hl7.org/ValueSet/contactentity-type|2.0.0), and a coding is recommended to come from this value set (codes = http://example.org/fhir/eu-ai-transparency/CodeSystem/eu-ai-contact-purpose-cs#ai-incident-reporting)EU AI Responsible Organization
fsh-generated/resources/Organization-organization-examplemed.jsonNone of the codings provided are in the value set 'Contact entity type' (http://terminology.hl7.org/ValueSet/contactentity-type|2.0.0), and a coding is recommended to come from this value set (codes = http://example.org/fhir/eu-ai-transparency/CodeSystem/eu-ai-contact-purpose-cs#dpo)EU AI Responsible Organization
fsh-generated/resources/Organization-organization-examplemed.jsonNone of the codings provided are in the value set 'Contact entity type' (http://terminology.hl7.org/ValueSet/contactentity-type|2.0.0), and a coding is recommended to come from this value set (codes = http://example.org/fhir/eu-ai-transparency/CodeSystem/eu-ai-contact-purpose-cs#ai-incident-reporting)EU AI Responsible Organization