KIOLA Implementation Guide
0.1.0 - STU1
KIOLA Implementation Guide - Local Development build (v0.1.0) built by the FHIR (HL7® FHIR® Standard) Build Tools. See the Directory of published versions
Official URL: https://fhir.ehealth-systems.at/artifacts/StructureDefinition/kiola-measurement-automatic-transmission-device | Version: 0.1.0 | |||
Active as of 2024-04-27 | Computable Name: KIOLAMeasurementAutomaticTransmissionDevice |
Device supporting automatic transmission of KIOLA vital data measurements, without entering the data manually.
Usage:
Description of Profiles, Differentials, Snapshots and how the different presentations work.
This structure is derived from KIOLAMeasurementDevice
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Device | KIOLAMeasurementDevice | |||
definition | 0..1 | Reference(KIOLA Measurement Automatic Transmission Device Definition) | The reference to the definition for the device | |
type | 1..1 | CodeableConcept | Type of measurement recording device Binding: KIOLA Automatic Transmission Measurement Device Types (required) | |
property:appPackage | S | 0..1 | BackboneElement | Identifier of the app required to transmit the measurements |
type | 1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) Required Pattern: At least the following | |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: https://fhir.ehealth-systems.at/kiola/device/kmc | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: app_package | |
valueQuantity | 0..0 | |||
valueCode | S | 1..1 | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) Binding: KMC App Packages (example) |
property:blockedDeviceType | S | 0..1 | BackboneElement | Blocked device types that should not be used for recording a measurement |
type | 1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) Required Pattern: At least the following | |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: https://fhir.ehealth-systems.at/kiola/device/kmc | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: blocked_device_type | |
valueQuantity | 0..0 | |||
valueCode | S | 1..1 | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) Binding: KIOLA Devices (example) |
property:multiMeasurement | S | 0..1 | BackboneElement | Record all measurements from the device. Otherwise only the latest measurement might be recorded. |
type | 1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) Required Pattern: At least the following | |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: https://fhir.ehealth-systems.at/kiola/device/kmc | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: device_multi_measurement | |
valueQuantity | 0..0 | |||
valueCode | S | 1..1 | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) Binding: KIOLA Boolean (required) |
property:measurementProperties | S | 0..1 | BackboneElement | Desired properties of the measurement, which are usually system and/or user dependent |
type | 1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) Binding: KIOLA Automatic Transmission Measurement Device Properties (extensible) | |
valueCode | 0..* | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) Binding: KIOLAMeasurementUnits (example) | |
Documentation for this format |
Path | Conformance | ValueSet | URI |
Device.type | required | KIOLAMeasurementAutomaticTransmissionDeviceTypeshttps://fhir.ehealth-systems.at/artifacts/ValueSet/KIOLAMeasurementAutomaticTransmissionDeviceTypes from this IG | |
Device.property:appPackage.valueCode | example | KMCAppPackageshttps://fhir.ehealth-systems.at/artifacts/ValueSet/KMCAppPackages from this IG | |
Device.property:blockedDeviceType.valueCode | example | KIOLADeviceshttps://fhir.ehealth-systems.at/artifacts/ValueSet/KIOLADevices from this IG | |
Device.property:multiMeasurement.valueCode | required | KIOLABooleanhttps://fhir.ehealth-systems.at/artifacts/ValueSet/KIOLABoolean from this IG | |
Device.property:measurementProperties.type | extensible | KIOLAMeasurementAutomaticTransmissionPropertieshttps://fhir.ehealth-systems.at/artifacts/ValueSet/KIOLAMeasurementAutomaticTransmissionProperties from this IG | |
Device.property:measurementProperties.valueCode | example | KIOLAMeasurementUnits (a valid code from KIOLA Dimension Codes AIT 11073)https://fhir.ehealth-systems.at/artifacts/ValueSet/KIOLAMeasurementUnits from this IG |
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Device | 0..* | KIOLAMeasurementDevice | Item used in healthcare | |
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created |
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored |
definition | 0..1 | Reference(KIOLA Measurement Automatic Transmission Device Definition) | The reference to the definition for the device | |
status | ?!Σ | 0..1 | code | active | inactive | entered-in-error | unknown Binding: FHIRDeviceStatus (required): The availability status of the device. |
type | S | 1..1 | CodeableConcept | Type of measurement recording device Binding: KIOLA Automatic Transmission Measurement Device Types (required) |
Slices for property | 0..* | BackboneElement | The actual configuration settings of a device as it actually operates, e.g., regulation status, time properties Slice: Unordered, Open by value:type | |
property:All Slices | Content/Rules for all slices | |||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
type | 1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) | |
property:uiReference | S | 0..1 | BackboneElement | UI reference which is used to display the device on a client |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
type | 1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) Required Pattern: At least the following | |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: https://fhir.ehealth-systems.at/kiola/device/kmc | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: ui_reference | |
valueCode | S | 1..1 | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) Binding: KMC UI References (example) |
property:appPackage | S | 0..1 | BackboneElement | Identifier of the app required to transmit the measurements |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
type | 1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) Required Pattern: At least the following | |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: https://fhir.ehealth-systems.at/kiola/device/kmc | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: app_package | |
valueCode | S | 1..1 | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) Binding: KMC App Packages (example) |
property:blockedDeviceType | S | 0..1 | BackboneElement | Blocked device types that should not be used for recording a measurement |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
type | 1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) Required Pattern: At least the following | |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: https://fhir.ehealth-systems.at/kiola/device/kmc | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: blocked_device_type | |
valueCode | S | 1..1 | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) Binding: KIOLA Devices (example) |
property:multiMeasurement | S | 0..1 | BackboneElement | Record all measurements from the device. Otherwise only the latest measurement might be recorded. |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
type | 1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) Required Pattern: At least the following | |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: https://fhir.ehealth-systems.at/kiola/device/kmc | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: device_multi_measurement | |
valueCode | S | 1..1 | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) Binding: KIOLA Boolean (required) |
property:measurementProperties | S | 0..1 | BackboneElement | Desired properties of the measurement, which are usually system and/or user dependent |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
type | 1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) Binding: KIOLA Automatic Transmission Measurement Device Properties (extensible) | |
valueCode | 0..* | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) Binding: KIOLAMeasurementUnits (example) | |
Documentation for this format |
Path | Conformance | ValueSet | URI |
Device.status | required | FHIRDeviceStatushttp://hl7.org/fhir/ValueSet/device-status|4.3.0 from the FHIR Standard | |
Device.type | required | KIOLAMeasurementAutomaticTransmissionDeviceTypeshttps://fhir.ehealth-systems.at/artifacts/ValueSet/KIOLAMeasurementAutomaticTransmissionDeviceTypes from this IG | |
Device.property:uiReference.valueCode | example | KMCUIReferenceshttps://fhir.ehealth-systems.at/artifacts/ValueSet/KMCUIReferences from this IG | |
Device.property:appPackage.valueCode | example | KMCAppPackageshttps://fhir.ehealth-systems.at/artifacts/ValueSet/KMCAppPackages from this IG | |
Device.property:blockedDeviceType.valueCode | example | KIOLADeviceshttps://fhir.ehealth-systems.at/artifacts/ValueSet/KIOLADevices from this IG | |
Device.property:multiMeasurement.valueCode | required | KIOLABooleanhttps://fhir.ehealth-systems.at/artifacts/ValueSet/KIOLABoolean from this IG | |
Device.property:measurementProperties.type | extensible | KIOLAMeasurementAutomaticTransmissionPropertieshttps://fhir.ehealth-systems.at/artifacts/ValueSet/KIOLAMeasurementAutomaticTransmissionProperties from this IG | |
Device.property:measurementProperties.valueCode | example | KIOLAMeasurementUnits (a valid code from KIOLA Dimension Codes AIT 11073)https://fhir.ehealth-systems.at/artifacts/ValueSet/KIOLAMeasurementUnits from this IG |
Name | Flags | Card. | Type | Description & Constraints | ||||
---|---|---|---|---|---|---|---|---|
Device | 0..* | KIOLAMeasurementDevice | Item used in healthcare | |||||
id | Σ | 0..1 | id | Logical id of this artifact | ||||
meta | Σ | 0..1 | Meta | Metadata about the resource | ||||
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||
language | 0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): IETF language tag
| |||||
text | 0..1 | Narrative | Text summary of the resource, for human interpretation | |||||
contained | 0..* | Resource | Contained, inline Resources dom-r4b: Containing new R4B resources within R4 resources may cause interoperability issues if instances are shared with R4 systems | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored | ||||
identifier | 0..* | Identifier | Instance identifier | |||||
definition | 0..1 | Reference(KIOLA Measurement Automatic Transmission Device Definition) | The reference to the definition for the device | |||||
udiCarrier | Σ | 0..* | BackboneElement | Unique Device Identifier (UDI) Barcode string | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
deviceIdentifier | Σ | 0..1 | string | Mandatory fixed portion of UDI | ||||
issuer | 0..1 | uri | UDI Issuing Organization | |||||
jurisdiction | 0..1 | uri | Regional UDI authority | |||||
carrierAIDC | Σ | 0..1 | base64Binary | UDI Machine Readable Barcode String | ||||
carrierHRF | Σ | 0..1 | string | UDI Human Readable Barcode String | ||||
entryType | 0..1 | code | barcode | rfid | manual + Binding: UDIEntryType (required): Codes to identify how UDI data was entered. | |||||
status | ?!Σ | 0..1 | code | active | inactive | entered-in-error | unknown Binding: FHIRDeviceStatus (required): The availability status of the device. | ||||
statusReason | 0..* | CodeableConcept | online | paused | standby | offline | not-ready | transduc-discon | hw-discon | off Binding: FHIRDeviceStatusReason (extensible): The availability status reason of the device. | |||||
distinctIdentifier | 0..1 | string | The distinct identification string | |||||
manufacturer | 0..1 | string | Name of device manufacturer | |||||
manufactureDate | 0..1 | dateTime | Date when the device was made | |||||
expirationDate | 0..1 | dateTime | Date and time of expiry of this device (if applicable) | |||||
lotNumber | 0..1 | string | Lot number of manufacture | |||||
serialNumber | 0..1 | string | Serial number assigned by the manufacturer | |||||
deviceName | 0..* | BackboneElement | The name of the device as given by the manufacturer | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
name | 1..1 | string | The name that identifies the device | |||||
type | 1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Binding: DeviceNameType (required): The type of name the device is referred by. | |||||
modelNumber | 0..1 | string | The manufacturer's model number for the device | |||||
partNumber | 0..1 | string | The part number or catalog number of the device | |||||
type | S | 1..1 | CodeableConcept | Type of measurement recording device Binding: KIOLA Automatic Transmission Measurement Device Types (required) | ||||
specialization | 0..* | BackboneElement | The capabilities supported on a device, the standards to which the device conforms for a particular purpose, and used for the communication | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
systemType | 1..1 | CodeableConcept | The standard that is used to operate and communicate | |||||
version | 0..1 | string | The version of the standard that is used to operate and communicate | |||||
version | 0..* | BackboneElement | The actual design of the device or software version running on the device | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
type | 0..1 | CodeableConcept | The type of the device version, e.g. manufacturer, approved, internal | |||||
component | 0..1 | Identifier | A single component of the device version | |||||
value | 1..1 | string | The version text | |||||
Slices for property | 0..* | BackboneElement | The actual configuration settings of a device as it actually operates, e.g., regulation status, time properties Slice: Unordered, Open by value:type | |||||
property:All Slices | Content/Rules for all slices | |||||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
type | 1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) | |||||
valueQuantity | 0..* | Quantity | Property value as a quantity | |||||
valueCode | 0..* | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) | |||||
property:uiReference | S | 0..1 | BackboneElement | UI reference which is used to display the device on a client | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
type | 1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) Required Pattern: At least the following | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: https://fhir.ehealth-systems.at/kiola/device/kmc | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: ui_reference | |||||
display | 0..1 | string | Representation defined by the system | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | 0..1 | string | Plain text representation of the concept | |||||
valueCode | S | 1..1 | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) Binding: KMC UI References (example) | ||||
property:appPackage | S | 0..1 | BackboneElement | Identifier of the app required to transmit the measurements | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
type | 1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) Required Pattern: At least the following | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: https://fhir.ehealth-systems.at/kiola/device/kmc | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: app_package | |||||
display | 0..1 | string | Representation defined by the system | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | 0..1 | string | Plain text representation of the concept | |||||
valueCode | S | 1..1 | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) Binding: KMC App Packages (example) | ||||
property:blockedDeviceType | S | 0..1 | BackboneElement | Blocked device types that should not be used for recording a measurement | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
type | 1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) Required Pattern: At least the following | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: https://fhir.ehealth-systems.at/kiola/device/kmc | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: blocked_device_type | |||||
display | 0..1 | string | Representation defined by the system | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | 0..1 | string | Plain text representation of the concept | |||||
valueCode | S | 1..1 | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) Binding: KIOLA Devices (example) | ||||
property:multiMeasurement | S | 0..1 | BackboneElement | Record all measurements from the device. Otherwise only the latest measurement might be recorded. | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
type | 1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) Required Pattern: At least the following | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: https://fhir.ehealth-systems.at/kiola/device/kmc | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: device_multi_measurement | |||||
display | 0..1 | string | Representation defined by the system | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | 0..1 | string | Plain text representation of the concept | |||||
valueCode | S | 1..1 | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) Binding: KIOLA Boolean (required) | ||||
property:measurementProperties | S | 0..1 | BackboneElement | Desired properties of the measurement, which are usually system and/or user dependent | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
type | 1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) Binding: KIOLA Automatic Transmission Measurement Device Properties (extensible) | |||||
valueQuantity | 0..* | Quantity | Property value as a quantity | |||||
valueCode | 0..* | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) Binding: KIOLAMeasurementUnits (example) | |||||
patient | 0..1 | Reference(Patient) | Patient to whom Device is affixed | |||||
owner | 0..1 | Reference(Organization) | Organization responsible for device | |||||
contact | 0..* | ContactPoint | Details for human/organization for support | |||||
location | 0..1 | Reference(Location) | Where the device is found | |||||
url | 0..1 | uri | Network address to contact device | |||||
note | 0..* | Annotation | Device notes and comments | |||||
safety | Σ | 0..* | CodeableConcept | Safety Characteristics of Device | ||||
parent | 0..1 | Reference(Device) | The device that this device is attached to or is part of | |||||
Documentation for this format |
Path | Conformance | ValueSet | URI | |||
Device.language | preferred | CommonLanguages
http://hl7.org/fhir/ValueSet/languages from the FHIR Standard | ||||
Device.udiCarrier.entryType | required | UDIEntryTypehttp://hl7.org/fhir/ValueSet/udi-entry-type|4.3.0 from the FHIR Standard | ||||
Device.status | required | FHIRDeviceStatushttp://hl7.org/fhir/ValueSet/device-status|4.3.0 from the FHIR Standard | ||||
Device.statusReason | extensible | FHIRDeviceStatusReasonhttp://hl7.org/fhir/ValueSet/device-status-reason from the FHIR Standard | ||||
Device.deviceName.type | required | DeviceNameTypehttp://hl7.org/fhir/ValueSet/device-nametype|4.3.0 from the FHIR Standard | ||||
Device.type | required | KIOLAMeasurementAutomaticTransmissionDeviceTypeshttps://fhir.ehealth-systems.at/artifacts/ValueSet/KIOLAMeasurementAutomaticTransmissionDeviceTypes from this IG | ||||
Device.property:uiReference.valueCode | example | KMCUIReferenceshttps://fhir.ehealth-systems.at/artifacts/ValueSet/KMCUIReferences from this IG | ||||
Device.property:appPackage.valueCode | example | KMCAppPackageshttps://fhir.ehealth-systems.at/artifacts/ValueSet/KMCAppPackages from this IG | ||||
Device.property:blockedDeviceType.valueCode | example | KIOLADeviceshttps://fhir.ehealth-systems.at/artifacts/ValueSet/KIOLADevices from this IG | ||||
Device.property:multiMeasurement.valueCode | required | KIOLABooleanhttps://fhir.ehealth-systems.at/artifacts/ValueSet/KIOLABoolean from this IG | ||||
Device.property:measurementProperties.type | extensible | KIOLAMeasurementAutomaticTransmissionPropertieshttps://fhir.ehealth-systems.at/artifacts/ValueSet/KIOLAMeasurementAutomaticTransmissionProperties from this IG | ||||
Device.property:measurementProperties.valueCode | example | KIOLAMeasurementUnits (a valid code from KIOLA Dimension Codes AIT 11073)https://fhir.ehealth-systems.at/artifacts/ValueSet/KIOLAMeasurementUnits from this IG |
This structure is derived from KIOLAMeasurementDevice
Differential View
This structure is derived from KIOLAMeasurementDevice
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Device | KIOLAMeasurementDevice | |||
definition | 0..1 | Reference(KIOLA Measurement Automatic Transmission Device Definition) | The reference to the definition for the device | |
type | 1..1 | CodeableConcept | Type of measurement recording device Binding: KIOLA Automatic Transmission Measurement Device Types (required) | |
property:appPackage | S | 0..1 | BackboneElement | Identifier of the app required to transmit the measurements |
type | 1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) Required Pattern: At least the following | |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: https://fhir.ehealth-systems.at/kiola/device/kmc | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: app_package | |
valueQuantity | 0..0 | |||
valueCode | S | 1..1 | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) Binding: KMC App Packages (example) |
property:blockedDeviceType | S | 0..1 | BackboneElement | Blocked device types that should not be used for recording a measurement |
type | 1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) Required Pattern: At least the following | |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: https://fhir.ehealth-systems.at/kiola/device/kmc | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: blocked_device_type | |
valueQuantity | 0..0 | |||
valueCode | S | 1..1 | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) Binding: KIOLA Devices (example) |
property:multiMeasurement | S | 0..1 | BackboneElement | Record all measurements from the device. Otherwise only the latest measurement might be recorded. |
type | 1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) Required Pattern: At least the following | |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: https://fhir.ehealth-systems.at/kiola/device/kmc | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: device_multi_measurement | |
valueQuantity | 0..0 | |||
valueCode | S | 1..1 | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) Binding: KIOLA Boolean (required) |
property:measurementProperties | S | 0..1 | BackboneElement | Desired properties of the measurement, which are usually system and/or user dependent |
type | 1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) Binding: KIOLA Automatic Transmission Measurement Device Properties (extensible) | |
valueCode | 0..* | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) Binding: KIOLAMeasurementUnits (example) | |
Documentation for this format |
Path | Conformance | ValueSet | URI |
Device.type | required | KIOLAMeasurementAutomaticTransmissionDeviceTypeshttps://fhir.ehealth-systems.at/artifacts/ValueSet/KIOLAMeasurementAutomaticTransmissionDeviceTypes from this IG | |
Device.property:appPackage.valueCode | example | KMCAppPackageshttps://fhir.ehealth-systems.at/artifacts/ValueSet/KMCAppPackages from this IG | |
Device.property:blockedDeviceType.valueCode | example | KIOLADeviceshttps://fhir.ehealth-systems.at/artifacts/ValueSet/KIOLADevices from this IG | |
Device.property:multiMeasurement.valueCode | required | KIOLABooleanhttps://fhir.ehealth-systems.at/artifacts/ValueSet/KIOLABoolean from this IG | |
Device.property:measurementProperties.type | extensible | KIOLAMeasurementAutomaticTransmissionPropertieshttps://fhir.ehealth-systems.at/artifacts/ValueSet/KIOLAMeasurementAutomaticTransmissionProperties from this IG | |
Device.property:measurementProperties.valueCode | example | KIOLAMeasurementUnits (a valid code from KIOLA Dimension Codes AIT 11073)https://fhir.ehealth-systems.at/artifacts/ValueSet/KIOLAMeasurementUnits from this IG |
Key Elements View
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Device | 0..* | KIOLAMeasurementDevice | Item used in healthcare | |
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created |
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored |
definition | 0..1 | Reference(KIOLA Measurement Automatic Transmission Device Definition) | The reference to the definition for the device | |
status | ?!Σ | 0..1 | code | active | inactive | entered-in-error | unknown Binding: FHIRDeviceStatus (required): The availability status of the device. |
type | S | 1..1 | CodeableConcept | Type of measurement recording device Binding: KIOLA Automatic Transmission Measurement Device Types (required) |
Slices for property | 0..* | BackboneElement | The actual configuration settings of a device as it actually operates, e.g., regulation status, time properties Slice: Unordered, Open by value:type | |
property:All Slices | Content/Rules for all slices | |||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
type | 1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) | |
property:uiReference | S | 0..1 | BackboneElement | UI reference which is used to display the device on a client |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
type | 1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) Required Pattern: At least the following | |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: https://fhir.ehealth-systems.at/kiola/device/kmc | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: ui_reference | |
valueCode | S | 1..1 | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) Binding: KMC UI References (example) |
property:appPackage | S | 0..1 | BackboneElement | Identifier of the app required to transmit the measurements |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
type | 1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) Required Pattern: At least the following | |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: https://fhir.ehealth-systems.at/kiola/device/kmc | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: app_package | |
valueCode | S | 1..1 | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) Binding: KMC App Packages (example) |
property:blockedDeviceType | S | 0..1 | BackboneElement | Blocked device types that should not be used for recording a measurement |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
type | 1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) Required Pattern: At least the following | |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: https://fhir.ehealth-systems.at/kiola/device/kmc | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: blocked_device_type | |
valueCode | S | 1..1 | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) Binding: KIOLA Devices (example) |
property:multiMeasurement | S | 0..1 | BackboneElement | Record all measurements from the device. Otherwise only the latest measurement might be recorded. |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
type | 1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) Required Pattern: At least the following | |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: https://fhir.ehealth-systems.at/kiola/device/kmc | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: device_multi_measurement | |
valueCode | S | 1..1 | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) Binding: KIOLA Boolean (required) |
property:measurementProperties | S | 0..1 | BackboneElement | Desired properties of the measurement, which are usually system and/or user dependent |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
type | 1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) Binding: KIOLA Automatic Transmission Measurement Device Properties (extensible) | |
valueCode | 0..* | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) Binding: KIOLAMeasurementUnits (example) | |
Documentation for this format |
Path | Conformance | ValueSet | URI |
Device.status | required | FHIRDeviceStatushttp://hl7.org/fhir/ValueSet/device-status|4.3.0 from the FHIR Standard | |
Device.type | required | KIOLAMeasurementAutomaticTransmissionDeviceTypeshttps://fhir.ehealth-systems.at/artifacts/ValueSet/KIOLAMeasurementAutomaticTransmissionDeviceTypes from this IG | |
Device.property:uiReference.valueCode | example | KMCUIReferenceshttps://fhir.ehealth-systems.at/artifacts/ValueSet/KMCUIReferences from this IG | |
Device.property:appPackage.valueCode | example | KMCAppPackageshttps://fhir.ehealth-systems.at/artifacts/ValueSet/KMCAppPackages from this IG | |
Device.property:blockedDeviceType.valueCode | example | KIOLADeviceshttps://fhir.ehealth-systems.at/artifacts/ValueSet/KIOLADevices from this IG | |
Device.property:multiMeasurement.valueCode | required | KIOLABooleanhttps://fhir.ehealth-systems.at/artifacts/ValueSet/KIOLABoolean from this IG | |
Device.property:measurementProperties.type | extensible | KIOLAMeasurementAutomaticTransmissionPropertieshttps://fhir.ehealth-systems.at/artifacts/ValueSet/KIOLAMeasurementAutomaticTransmissionProperties from this IG | |
Device.property:measurementProperties.valueCode | example | KIOLAMeasurementUnits (a valid code from KIOLA Dimension Codes AIT 11073)https://fhir.ehealth-systems.at/artifacts/ValueSet/KIOLAMeasurementUnits from this IG |
Snapshot View
Name | Flags | Card. | Type | Description & Constraints | ||||
---|---|---|---|---|---|---|---|---|
Device | 0..* | KIOLAMeasurementDevice | Item used in healthcare | |||||
id | Σ | 0..1 | id | Logical id of this artifact | ||||
meta | Σ | 0..1 | Meta | Metadata about the resource | ||||
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||
language | 0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): IETF language tag
| |||||
text | 0..1 | Narrative | Text summary of the resource, for human interpretation | |||||
contained | 0..* | Resource | Contained, inline Resources dom-r4b: Containing new R4B resources within R4 resources may cause interoperability issues if instances are shared with R4 systems | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored | ||||
identifier | 0..* | Identifier | Instance identifier | |||||
definition | 0..1 | Reference(KIOLA Measurement Automatic Transmission Device Definition) | The reference to the definition for the device | |||||
udiCarrier | Σ | 0..* | BackboneElement | Unique Device Identifier (UDI) Barcode string | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
deviceIdentifier | Σ | 0..1 | string | Mandatory fixed portion of UDI | ||||
issuer | 0..1 | uri | UDI Issuing Organization | |||||
jurisdiction | 0..1 | uri | Regional UDI authority | |||||
carrierAIDC | Σ | 0..1 | base64Binary | UDI Machine Readable Barcode String | ||||
carrierHRF | Σ | 0..1 | string | UDI Human Readable Barcode String | ||||
entryType | 0..1 | code | barcode | rfid | manual + Binding: UDIEntryType (required): Codes to identify how UDI data was entered. | |||||
status | ?!Σ | 0..1 | code | active | inactive | entered-in-error | unknown Binding: FHIRDeviceStatus (required): The availability status of the device. | ||||
statusReason | 0..* | CodeableConcept | online | paused | standby | offline | not-ready | transduc-discon | hw-discon | off Binding: FHIRDeviceStatusReason (extensible): The availability status reason of the device. | |||||
distinctIdentifier | 0..1 | string | The distinct identification string | |||||
manufacturer | 0..1 | string | Name of device manufacturer | |||||
manufactureDate | 0..1 | dateTime | Date when the device was made | |||||
expirationDate | 0..1 | dateTime | Date and time of expiry of this device (if applicable) | |||||
lotNumber | 0..1 | string | Lot number of manufacture | |||||
serialNumber | 0..1 | string | Serial number assigned by the manufacturer | |||||
deviceName | 0..* | BackboneElement | The name of the device as given by the manufacturer | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
name | 1..1 | string | The name that identifies the device | |||||
type | 1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Binding: DeviceNameType (required): The type of name the device is referred by. | |||||
modelNumber | 0..1 | string | The manufacturer's model number for the device | |||||
partNumber | 0..1 | string | The part number or catalog number of the device | |||||
type | S | 1..1 | CodeableConcept | Type of measurement recording device Binding: KIOLA Automatic Transmission Measurement Device Types (required) | ||||
specialization | 0..* | BackboneElement | The capabilities supported on a device, the standards to which the device conforms for a particular purpose, and used for the communication | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
systemType | 1..1 | CodeableConcept | The standard that is used to operate and communicate | |||||
version | 0..1 | string | The version of the standard that is used to operate and communicate | |||||
version | 0..* | BackboneElement | The actual design of the device or software version running on the device | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
type | 0..1 | CodeableConcept | The type of the device version, e.g. manufacturer, approved, internal | |||||
component | 0..1 | Identifier | A single component of the device version | |||||
value | 1..1 | string | The version text | |||||
Slices for property | 0..* | BackboneElement | The actual configuration settings of a device as it actually operates, e.g., regulation status, time properties Slice: Unordered, Open by value:type | |||||
property:All Slices | Content/Rules for all slices | |||||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
type | 1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) | |||||
valueQuantity | 0..* | Quantity | Property value as a quantity | |||||
valueCode | 0..* | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) | |||||
property:uiReference | S | 0..1 | BackboneElement | UI reference which is used to display the device on a client | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
type | 1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) Required Pattern: At least the following | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: https://fhir.ehealth-systems.at/kiola/device/kmc | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: ui_reference | |||||
display | 0..1 | string | Representation defined by the system | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | 0..1 | string | Plain text representation of the concept | |||||
valueCode | S | 1..1 | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) Binding: KMC UI References (example) | ||||
property:appPackage | S | 0..1 | BackboneElement | Identifier of the app required to transmit the measurements | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
type | 1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) Required Pattern: At least the following | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: https://fhir.ehealth-systems.at/kiola/device/kmc | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: app_package | |||||
display | 0..1 | string | Representation defined by the system | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | 0..1 | string | Plain text representation of the concept | |||||
valueCode | S | 1..1 | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) Binding: KMC App Packages (example) | ||||
property:blockedDeviceType | S | 0..1 | BackboneElement | Blocked device types that should not be used for recording a measurement | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
type | 1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) Required Pattern: At least the following | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: https://fhir.ehealth-systems.at/kiola/device/kmc | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: blocked_device_type | |||||
display | 0..1 | string | Representation defined by the system | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | 0..1 | string | Plain text representation of the concept | |||||
valueCode | S | 1..1 | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) Binding: KIOLA Devices (example) | ||||
property:multiMeasurement | S | 0..1 | BackboneElement | Record all measurements from the device. Otherwise only the latest measurement might be recorded. | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
type | 1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) Required Pattern: At least the following | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: https://fhir.ehealth-systems.at/kiola/device/kmc | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: device_multi_measurement | |||||
display | 0..1 | string | Representation defined by the system | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | 0..1 | string | Plain text representation of the concept | |||||
valueCode | S | 1..1 | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) Binding: KIOLA Boolean (required) | ||||
property:measurementProperties | S | 0..1 | BackboneElement | Desired properties of the measurement, which are usually system and/or user dependent | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
type | 1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) Binding: KIOLA Automatic Transmission Measurement Device Properties (extensible) | |||||
valueQuantity | 0..* | Quantity | Property value as a quantity | |||||
valueCode | 0..* | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) Binding: KIOLAMeasurementUnits (example) | |||||
patient | 0..1 | Reference(Patient) | Patient to whom Device is affixed | |||||
owner | 0..1 | Reference(Organization) | Organization responsible for device | |||||
contact | 0..* | ContactPoint | Details for human/organization for support | |||||
location | 0..1 | Reference(Location) | Where the device is found | |||||
url | 0..1 | uri | Network address to contact device | |||||
note | 0..* | Annotation | Device notes and comments | |||||
safety | Σ | 0..* | CodeableConcept | Safety Characteristics of Device | ||||
parent | 0..1 | Reference(Device) | The device that this device is attached to or is part of | |||||
Documentation for this format |
Path | Conformance | ValueSet | URI | |||
Device.language | preferred | CommonLanguages
http://hl7.org/fhir/ValueSet/languages from the FHIR Standard | ||||
Device.udiCarrier.entryType | required | UDIEntryTypehttp://hl7.org/fhir/ValueSet/udi-entry-type|4.3.0 from the FHIR Standard | ||||
Device.status | required | FHIRDeviceStatushttp://hl7.org/fhir/ValueSet/device-status|4.3.0 from the FHIR Standard | ||||
Device.statusReason | extensible | FHIRDeviceStatusReasonhttp://hl7.org/fhir/ValueSet/device-status-reason from the FHIR Standard | ||||
Device.deviceName.type | required | DeviceNameTypehttp://hl7.org/fhir/ValueSet/device-nametype|4.3.0 from the FHIR Standard | ||||
Device.type | required | KIOLAMeasurementAutomaticTransmissionDeviceTypeshttps://fhir.ehealth-systems.at/artifacts/ValueSet/KIOLAMeasurementAutomaticTransmissionDeviceTypes from this IG | ||||
Device.property:uiReference.valueCode | example | KMCUIReferenceshttps://fhir.ehealth-systems.at/artifacts/ValueSet/KMCUIReferences from this IG | ||||
Device.property:appPackage.valueCode | example | KMCAppPackageshttps://fhir.ehealth-systems.at/artifacts/ValueSet/KMCAppPackages from this IG | ||||
Device.property:blockedDeviceType.valueCode | example | KIOLADeviceshttps://fhir.ehealth-systems.at/artifacts/ValueSet/KIOLADevices from this IG | ||||
Device.property:multiMeasurement.valueCode | required | KIOLABooleanhttps://fhir.ehealth-systems.at/artifacts/ValueSet/KIOLABoolean from this IG | ||||
Device.property:measurementProperties.type | extensible | KIOLAMeasurementAutomaticTransmissionPropertieshttps://fhir.ehealth-systems.at/artifacts/ValueSet/KIOLAMeasurementAutomaticTransmissionProperties from this IG | ||||
Device.property:measurementProperties.valueCode | example | KIOLAMeasurementUnits (a valid code from KIOLA Dimension Codes AIT 11073)https://fhir.ehealth-systems.at/artifacts/ValueSet/KIOLAMeasurementUnits from this IG |
This structure is derived from KIOLAMeasurementDevice
Other representations of profile: CSV, Excel, Schematron
IG © 2023+ . Package kiola-implementation-guide#0.1.0 based on FHIR® 4.3.0. Generated 2024-04-27
Links: Table of Contents |
QA Report