KIOLA Implementation Guide
0.1.0 - STU1
KIOLA Implementation Guide - Local Development build (v0.1.0) built by the FHIR (HL7® FHIR® Standard) Build Tools. See the Directory of published versions
Official URL: https://fhir.ehealth-systems.at/artifacts/StructureDefinition/kiola-measurement-manual-entry-device-definition | Version: 0.1.0 | |||
Active as of 2024-04-27 | Computable Name: KIOLAMeasurementManualEntryDeviceDefinition |
Definition of a device supporting manual data entry of KIOLA vital data measurements.
Usage:
Description of Profiles, Differentials, Snapshots and how the different presentations work.
This structure is derived from KIOLAMeasurementDeviceDefinition
Name | Flags | Card. | Type | Description & Constraints![]() |
---|---|---|---|---|
![]() ![]() |
KIOLAMeasurementDeviceDefinition | |||
![]() ![]() ![]() |
1..1 | CodeableConcept | Type of measurement recording device Required Pattern: At least the following | |
![]() ![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
![]() ![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: https://fhir.ehealth-systems.at/kiola/device | |
![]() ![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: SDC | |
![]() |
Name | Flags | Card. | Type | Description & Constraints![]() |
---|---|---|---|---|
![]() ![]() |
0..* | KIOLAMeasurementDeviceDefinition | An instance of a medical-related component of a medical device | |
![]() ![]() ![]() |
?!Σ | 0..1 | uri | A set of rules under which this content was created |
![]() ![]() ![]() |
?! | 0..* | Extension | Extensions that cannot be ignored |
![]() ![]() ![]() |
S | 1..1 | CodeableConcept | Type of measurement recording device Binding: KIOLA Measurement Device Types (required) Required Pattern: At least the following |
![]() ![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
![]() ![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: https://fhir.ehealth-systems.at/kiola/device | |
![]() ![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: SDC | |
![]() ![]() ![]() |
0..* | BackboneElement | The actual configuration settings of a device as it actually operates, e.g., regulation status, time properties Slice: Unordered, Open by value:type | |
![]() ![]() ![]() ![]() |
Content/Rules for all slices | |||
![]() ![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
![]() ![]() ![]() ![]() ![]() |
1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) | |
![]() ![]() ![]() ![]() |
S | 0..1 | BackboneElement | UI reference which is used to display the device on a client |
![]() ![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
![]() ![]() ![]() ![]() ![]() |
1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) Required Pattern: At least the following | |
![]() ![]() ![]() ![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: https://fhir.ehealth-systems.at/kiola/device/kmc | |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: ui_reference | |
![]() ![]() ![]() ![]() ![]() |
S | 1..1 | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) Binding: KMC UI References (example) |
![]() |
Path | Conformance | ValueSet / Code | URI |
DeviceDefinition.type | required | Pattern: SDChttps://fhir.ehealth-systems.at/artifacts/ValueSet/KIOLAMeasurementDeviceTypes from this IG | |
DeviceDefinition.property:uiReference.valueCode | example | KMCUIReferenceshttps://fhir.ehealth-systems.at/artifacts/ValueSet/KMCUIReferences from this IG |
Name | Flags | Card. | Type | Description & Constraints![]() | ||||
---|---|---|---|---|---|---|---|---|
![]() ![]() |
0..* | KIOLAMeasurementDeviceDefinition | An instance of a medical-related component of a medical device | |||||
![]() ![]() ![]() |
Σ | 0..1 | id | Logical id of this artifact | ||||
![]() ![]() ![]() |
Σ | 0..1 | Meta | Metadata about the resource | ||||
![]() ![]() ![]() |
?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||
![]() ![]() ![]() |
0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): IETF language tag
| |||||
![]() ![]() ![]() |
0..1 | Narrative | Text summary of the resource, for human interpretation | |||||
![]() ![]() ![]() |
0..* | Resource | Contained, inline Resources dom-r4b: Containing new R4B resources within R4 resources may cause interoperability issues if instances are shared with R4 systems | |||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() |
?! | 0..* | Extension | Extensions that cannot be ignored | ||||
![]() ![]() ![]() |
0..* | Identifier | Instance identifier | |||||
![]() ![]() ![]() |
0..* | BackboneElement | Unique Device Identifier (UDI) Barcode string | |||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() |
1..1 | string | The identifier that is to be associated with every Device that references this DeviceDefintiion for the issuer and jurisdication porvided in the DeviceDefinition.udiDeviceIdentifier | |||||
![]() ![]() ![]() ![]() |
1..1 | uri | The organization that assigns the identifier algorithm | |||||
![]() ![]() ![]() ![]() |
1..1 | uri | The jurisdiction to which the deviceIdentifier applies | |||||
![]() ![]() ![]() |
0..1 | Name of device manufacturer | ||||||
![]() ![]() ![]() ![]() |
string | |||||||
![]() ![]() ![]() ![]() |
Reference(Organization) | |||||||
![]() ![]() ![]() |
0..* | BackboneElement | A name given to the device to identify it | |||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() |
1..1 | string | The name of the device | |||||
![]() ![]() ![]() ![]() |
1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Binding: DeviceNameType (required): The type of name the device is referred by. | |||||
![]() ![]() ![]() |
0..1 | string | The model number for the device | |||||
![]() ![]() ![]() |
S | 1..1 | CodeableConcept | Type of measurement recording device Binding: KIOLA Measurement Device Types (required) Required Pattern: At least the following | ||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: https://fhir.ehealth-systems.at/kiola/device | |||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Version of the system - if relevant | |||||
![]() ![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: SDC | |||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Representation defined by the system | |||||
![]() ![]() ![]() ![]() ![]() |
0..1 | boolean | If this coding was chosen directly by the user | |||||
![]() ![]() ![]() ![]() |
0..1 | string | Plain text representation of the concept | |||||
![]() ![]() ![]() |
0..* | BackboneElement | The capabilities supported on a device, the standards to which the device conforms for a particular purpose, and used for the communication | |||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() |
1..1 | string | The standard that is used to operate and communicate | |||||
![]() ![]() ![]() ![]() |
0..1 | string | The version of the standard that is used to operate and communicate | |||||
![]() ![]() ![]() |
0..* | string | Available versions | |||||
![]() ![]() ![]() |
Σ | 0..* | CodeableConcept | Safety characteristics of the device Binding: device-safety (example) | ||||
![]() ![]() ![]() |
0..* | ProductShelfLife | Shelf Life and storage information | |||||
![]() ![]() ![]() |
0..1 | ProdCharacteristic | Dimensions, color etc. | |||||
![]() ![]() ![]() |
0..* | CodeableConcept | Language code for the human-readable text strings produced by the device (all supported) | |||||
![]() ![]() ![]() |
0..* | BackboneElement | Device capabilities | |||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() |
1..1 | CodeableConcept | Type of capability | |||||
![]() ![]() ![]() ![]() |
0..* | CodeableConcept | Description of capability | |||||
![]() ![]() ![]() |
0..* | BackboneElement | The actual configuration settings of a device as it actually operates, e.g., regulation status, time properties Slice: Unordered, Open by value:type | |||||
![]() ![]() ![]() ![]() |
Content/Rules for all slices | |||||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() ![]() |
1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) | |||||
![]() ![]() ![]() ![]() ![]() |
0..* | Quantity | Property value as a quantity | |||||
![]() ![]() ![]() ![]() ![]() |
0..* | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) | |||||
![]() ![]() ![]() ![]() |
S | 0..1 | BackboneElement | UI reference which is used to display the device on a client | ||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() ![]() |
1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) Required Pattern: At least the following | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: https://fhir.ehealth-systems.at/kiola/device/kmc | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Version of the system - if relevant | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: ui_reference | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Representation defined by the system | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | boolean | If this coding was chosen directly by the user | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Plain text representation of the concept | |||||
![]() ![]() ![]() ![]() ![]() |
S | 1..1 | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) Binding: KMC UI References (example) | ||||
![]() ![]() ![]() |
0..1 | Reference(Organization) | Organization responsible for device | |||||
![]() ![]() ![]() |
0..* | ContactPoint | Details for human/organization for support | |||||
![]() ![]() ![]() |
0..1 | uri | Network address to contact device | |||||
![]() ![]() ![]() |
0..1 | uri | Access to on-line information | |||||
![]() ![]() ![]() |
0..* | Annotation | Device notes and comments | |||||
![]() ![]() ![]() |
0..1 | Quantity | The quantity of the device present in the packaging (e.g. the number of devices present in a pack, or the number of devices in the same package of the medicinal product) | |||||
![]() ![]() ![]() |
Σ | 0..1 | Reference(DeviceDefinition) | The parent device it can be part of | ||||
![]() ![]() ![]() |
0..* | BackboneElement | A substance used to create the material(s) of which the device is made | |||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() |
1..1 | CodeableConcept | The substance | |||||
![]() ![]() ![]() ![]() |
0..1 | boolean | Indicates an alternative material of the device | |||||
![]() ![]() ![]() ![]() |
0..1 | boolean | Whether the substance is a known or suspected allergen | |||||
![]() |
Path | Conformance | ValueSet / Code | URI | |||
DeviceDefinition.language | preferred | CommonLanguages
http://hl7.org/fhir/ValueSet/languages from the FHIR Standard | ||||
DeviceDefinition.deviceName.type | required | DeviceNameTypehttp://hl7.org/fhir/ValueSet/device-nametype|4.3.0 from the FHIR Standard | ||||
DeviceDefinition.type | required | Pattern: SDChttps://fhir.ehealth-systems.at/artifacts/ValueSet/KIOLAMeasurementDeviceTypes from this IG | ||||
DeviceDefinition.safety | example | http://hl7.org/fhir/ValueSet/device-safetyhttp://hl7.org/fhir/ValueSet/device-safety | ||||
DeviceDefinition.property:uiReference.valueCode | example | KMCUIReferenceshttps://fhir.ehealth-systems.at/artifacts/ValueSet/KMCUIReferences from this IG |
This structure is derived from KIOLAMeasurementDeviceDefinition
Differential View
This structure is derived from KIOLAMeasurementDeviceDefinition
Name | Flags | Card. | Type | Description & Constraints![]() |
---|---|---|---|---|
![]() ![]() |
KIOLAMeasurementDeviceDefinition | |||
![]() ![]() ![]() |
1..1 | CodeableConcept | Type of measurement recording device Required Pattern: At least the following | |
![]() ![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
![]() ![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: https://fhir.ehealth-systems.at/kiola/device | |
![]() ![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: SDC | |
![]() |
Key Elements View
Name | Flags | Card. | Type | Description & Constraints![]() |
---|---|---|---|---|
![]() ![]() |
0..* | KIOLAMeasurementDeviceDefinition | An instance of a medical-related component of a medical device | |
![]() ![]() ![]() |
?!Σ | 0..1 | uri | A set of rules under which this content was created |
![]() ![]() ![]() |
?! | 0..* | Extension | Extensions that cannot be ignored |
![]() ![]() ![]() |
S | 1..1 | CodeableConcept | Type of measurement recording device Binding: KIOLA Measurement Device Types (required) Required Pattern: At least the following |
![]() ![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
![]() ![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: https://fhir.ehealth-systems.at/kiola/device | |
![]() ![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: SDC | |
![]() ![]() ![]() |
0..* | BackboneElement | The actual configuration settings of a device as it actually operates, e.g., regulation status, time properties Slice: Unordered, Open by value:type | |
![]() ![]() ![]() ![]() |
Content/Rules for all slices | |||
![]() ![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
![]() ![]() ![]() ![]() ![]() |
1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) | |
![]() ![]() ![]() ![]() |
S | 0..1 | BackboneElement | UI reference which is used to display the device on a client |
![]() ![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
![]() ![]() ![]() ![]() ![]() |
1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) Required Pattern: At least the following | |
![]() ![]() ![]() ![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: https://fhir.ehealth-systems.at/kiola/device/kmc | |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: ui_reference | |
![]() ![]() ![]() ![]() ![]() |
S | 1..1 | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) Binding: KMC UI References (example) |
![]() |
Path | Conformance | ValueSet / Code | URI |
DeviceDefinition.type | required | Pattern: SDChttps://fhir.ehealth-systems.at/artifacts/ValueSet/KIOLAMeasurementDeviceTypes from this IG | |
DeviceDefinition.property:uiReference.valueCode | example | KMCUIReferenceshttps://fhir.ehealth-systems.at/artifacts/ValueSet/KMCUIReferences from this IG |
Snapshot View
Name | Flags | Card. | Type | Description & Constraints![]() | ||||
---|---|---|---|---|---|---|---|---|
![]() ![]() |
0..* | KIOLAMeasurementDeviceDefinition | An instance of a medical-related component of a medical device | |||||
![]() ![]() ![]() |
Σ | 0..1 | id | Logical id of this artifact | ||||
![]() ![]() ![]() |
Σ | 0..1 | Meta | Metadata about the resource | ||||
![]() ![]() ![]() |
?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||
![]() ![]() ![]() |
0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): IETF language tag
| |||||
![]() ![]() ![]() |
0..1 | Narrative | Text summary of the resource, for human interpretation | |||||
![]() ![]() ![]() |
0..* | Resource | Contained, inline Resources dom-r4b: Containing new R4B resources within R4 resources may cause interoperability issues if instances are shared with R4 systems | |||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() |
?! | 0..* | Extension | Extensions that cannot be ignored | ||||
![]() ![]() ![]() |
0..* | Identifier | Instance identifier | |||||
![]() ![]() ![]() |
0..* | BackboneElement | Unique Device Identifier (UDI) Barcode string | |||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() |
1..1 | string | The identifier that is to be associated with every Device that references this DeviceDefintiion for the issuer and jurisdication porvided in the DeviceDefinition.udiDeviceIdentifier | |||||
![]() ![]() ![]() ![]() |
1..1 | uri | The organization that assigns the identifier algorithm | |||||
![]() ![]() ![]() ![]() |
1..1 | uri | The jurisdiction to which the deviceIdentifier applies | |||||
![]() ![]() ![]() |
0..1 | Name of device manufacturer | ||||||
![]() ![]() ![]() ![]() |
string | |||||||
![]() ![]() ![]() ![]() |
Reference(Organization) | |||||||
![]() ![]() ![]() |
0..* | BackboneElement | A name given to the device to identify it | |||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() |
1..1 | string | The name of the device | |||||
![]() ![]() ![]() ![]() |
1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Binding: DeviceNameType (required): The type of name the device is referred by. | |||||
![]() ![]() ![]() |
0..1 | string | The model number for the device | |||||
![]() ![]() ![]() |
S | 1..1 | CodeableConcept | Type of measurement recording device Binding: KIOLA Measurement Device Types (required) Required Pattern: At least the following | ||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: https://fhir.ehealth-systems.at/kiola/device | |||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Version of the system - if relevant | |||||
![]() ![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: SDC | |||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Representation defined by the system | |||||
![]() ![]() ![]() ![]() ![]() |
0..1 | boolean | If this coding was chosen directly by the user | |||||
![]() ![]() ![]() ![]() |
0..1 | string | Plain text representation of the concept | |||||
![]() ![]() ![]() |
0..* | BackboneElement | The capabilities supported on a device, the standards to which the device conforms for a particular purpose, and used for the communication | |||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() |
1..1 | string | The standard that is used to operate and communicate | |||||
![]() ![]() ![]() ![]() |
0..1 | string | The version of the standard that is used to operate and communicate | |||||
![]() ![]() ![]() |
0..* | string | Available versions | |||||
![]() ![]() ![]() |
Σ | 0..* | CodeableConcept | Safety characteristics of the device Binding: device-safety (example) | ||||
![]() ![]() ![]() |
0..* | ProductShelfLife | Shelf Life and storage information | |||||
![]() ![]() ![]() |
0..1 | ProdCharacteristic | Dimensions, color etc. | |||||
![]() ![]() ![]() |
0..* | CodeableConcept | Language code for the human-readable text strings produced by the device (all supported) | |||||
![]() ![]() ![]() |
0..* | BackboneElement | Device capabilities | |||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() |
1..1 | CodeableConcept | Type of capability | |||||
![]() ![]() ![]() ![]() |
0..* | CodeableConcept | Description of capability | |||||
![]() ![]() ![]() |
0..* | BackboneElement | The actual configuration settings of a device as it actually operates, e.g., regulation status, time properties Slice: Unordered, Open by value:type | |||||
![]() ![]() ![]() ![]() |
Content/Rules for all slices | |||||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() ![]() |
1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) | |||||
![]() ![]() ![]() ![]() ![]() |
0..* | Quantity | Property value as a quantity | |||||
![]() ![]() ![]() ![]() ![]() |
0..* | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) | |||||
![]() ![]() ![]() ![]() |
S | 0..1 | BackboneElement | UI reference which is used to display the device on a client | ||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() ![]() |
1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) Required Pattern: At least the following | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: https://fhir.ehealth-systems.at/kiola/device/kmc | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Version of the system - if relevant | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: ui_reference | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Representation defined by the system | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | boolean | If this coding was chosen directly by the user | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Plain text representation of the concept | |||||
![]() ![]() ![]() ![]() ![]() |
S | 1..1 | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) Binding: KMC UI References (example) | ||||
![]() ![]() ![]() |
0..1 | Reference(Organization) | Organization responsible for device | |||||
![]() ![]() ![]() |
0..* | ContactPoint | Details for human/organization for support | |||||
![]() ![]() ![]() |
0..1 | uri | Network address to contact device | |||||
![]() ![]() ![]() |
0..1 | uri | Access to on-line information | |||||
![]() ![]() ![]() |
0..* | Annotation | Device notes and comments | |||||
![]() ![]() ![]() |
0..1 | Quantity | The quantity of the device present in the packaging (e.g. the number of devices present in a pack, or the number of devices in the same package of the medicinal product) | |||||
![]() ![]() ![]() |
Σ | 0..1 | Reference(DeviceDefinition) | The parent device it can be part of | ||||
![]() ![]() ![]() |
0..* | BackboneElement | A substance used to create the material(s) of which the device is made | |||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() |
1..1 | CodeableConcept | The substance | |||||
![]() ![]() ![]() ![]() |
0..1 | boolean | Indicates an alternative material of the device | |||||
![]() ![]() ![]() ![]() |
0..1 | boolean | Whether the substance is a known or suspected allergen | |||||
![]() |
Path | Conformance | ValueSet / Code | URI | |||
DeviceDefinition.language | preferred | CommonLanguages
http://hl7.org/fhir/ValueSet/languages from the FHIR Standard | ||||
DeviceDefinition.deviceName.type | required | DeviceNameTypehttp://hl7.org/fhir/ValueSet/device-nametype|4.3.0 from the FHIR Standard | ||||
DeviceDefinition.type | required | Pattern: SDChttps://fhir.ehealth-systems.at/artifacts/ValueSet/KIOLAMeasurementDeviceTypes from this IG | ||||
DeviceDefinition.safety | example | http://hl7.org/fhir/ValueSet/device-safetyhttp://hl7.org/fhir/ValueSet/device-safety | ||||
DeviceDefinition.property:uiReference.valueCode | example | KMCUIReferenceshttps://fhir.ehealth-systems.at/artifacts/ValueSet/KMCUIReferences from this IG |
This structure is derived from KIOLAMeasurementDeviceDefinition
Other representations of profile: CSV, Excel, Schematron