                KIOLA Implementation Guide
                0.1.0 - STU1
              
KIOLA Implementation Guide - Local Development build (v0.1.0) built by the FHIR (HL7® FHIR® Standard) Build Tools. See the Directory of published versions
| Official URL: https://fhir.ehealth-systems.at/artifacts/StructureDefinition/kiola-measurement-manual-entry-device-definition | Version: 0.1.0 | |||
| Active as of 2024-04-27 | Computable Name: KIOLAMeasurementManualEntryDeviceDefinition | |||
Definition of a device supporting manual data entry of KIOLA vital data measurements.
Usage:
Description of Profiles, Differentials, Snapshots and how the different presentations work.
This structure is derived from KIOLAMeasurementDeviceDefinition
| Name | Flags | Card. | Type | Description & Constraints  | 
|---|---|---|---|---|
|   DeviceDefinition | KIOLAMeasurementDeviceDefinition | |||
|    type | 1..1 | CodeableConcept | Type of measurement recording device Required Pattern: At least the following | |
|     coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
|      system | 1..1 | uri | Identity of the terminology system Fixed Value: https://fhir.ehealth-systems.at/kiola/device | |
|      code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: SDC | |
|  Documentation for this format | ||||
| Name | Flags | Card. | Type | Description & Constraints  | 
|---|---|---|---|---|
|   DeviceDefinition | 0..* | KIOLAMeasurementDeviceDefinition | An instance of a medical-related component of a medical device | |
|    implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created | 
|    modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored | 
|    type | S | 1..1 | CodeableConcept | Type of measurement recording device Binding: KIOLA Measurement Device Types (required) Required Pattern: At least the following | 
|     coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
|      system | 1..1 | uri | Identity of the terminology system Fixed Value: https://fhir.ehealth-systems.at/kiola/device | |
|      code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: SDC | |
|    Slices for property | 0..* | BackboneElement | The actual configuration settings of a device as it actually operates, e.g., regulation status, time properties Slice: Unordered, Open by value:type | |
|     property:All Slices | Content/Rules for all slices | |||
|      modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | 
|      type | 1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) | |
|     property:uiReference | S | 0..1 | BackboneElement | UI reference which is used to display the device on a client | 
|      modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | 
|      type | 1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) Required Pattern: At least the following | |
|       coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
|        system | 1..1 | uri | Identity of the terminology system Fixed Value: https://fhir.ehealth-systems.at/kiola/device/kmc | |
|        code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: ui_reference | |
|      valueCode | S | 1..1 | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) Binding: KMC UI References (example) | 
|  Documentation for this format | ||||
| Path | Conformance | ValueSet / Code | URI | 
| DeviceDefinition.type | required | Pattern: SDC https://fhir.ehealth-systems.at/artifacts/ValueSet/KIOLAMeasurementDeviceTypesfrom this IG | |
| DeviceDefinition.property:uiReference.valueCode | example | KMCUIReferences https://fhir.ehealth-systems.at/artifacts/ValueSet/KMCUIReferencesfrom this IG | 
| Name | Flags | Card. | Type | Description & Constraints  | ||||
|---|---|---|---|---|---|---|---|---|
|   DeviceDefinition | 0..* | KIOLAMeasurementDeviceDefinition | An instance of a medical-related component of a medical device | |||||
|    id | Σ | 0..1 | id | Logical id of this artifact | ||||
|    meta | Σ | 0..1 | Meta | Metadata about the resource | ||||
|    implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||
|    language | 0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): IETF language tag 
 | |||||
|    text | 0..1 | Narrative | Text summary of the resource, for human interpretation | |||||
|    contained | 0..* | Resource | Contained, inline Resources dom-r4b: Containing new R4B resources within R4 resources may cause interoperability issues if instances are shared with R4 systems | |||||
|    extension | 0..* | Extension | Additional content defined by implementations | |||||
|    modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored | ||||
|    identifier | 0..* | Identifier | Instance identifier | |||||
|    udiDeviceIdentifier | 0..* | BackboneElement | Unique Device Identifier (UDI) Barcode string | |||||
|     id | 0..1 | string | Unique id for inter-element referencing | |||||
|     extension | 0..* | Extension | Additional content defined by implementations | |||||
|     modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
|     deviceIdentifier | 1..1 | string | The identifier that is to be associated with every Device that references this DeviceDefintiion for the issuer and jurisdication porvided in the DeviceDefinition.udiDeviceIdentifier | |||||
|     issuer | 1..1 | uri | The organization that assigns the identifier algorithm | |||||
|     jurisdiction | 1..1 | uri | The jurisdiction to which the deviceIdentifier applies | |||||
|    manufacturer[x] | 0..1 | Name of device manufacturer | ||||||
|     manufacturerString | string | |||||||
|     manufacturerReference | Reference(Organization) | |||||||
|    deviceName | 0..* | BackboneElement | A name given to the device to identify it | |||||
|     id | 0..1 | string | Unique id for inter-element referencing | |||||
|     extension | 0..* | Extension | Additional content defined by implementations | |||||
|     modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
|     name | 1..1 | string | The name of the device | |||||
|     type | 1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Binding: DeviceNameType (required): The type of name the device is referred by. | |||||
|    modelNumber | 0..1 | string | The model number for the device | |||||
|    type | S | 1..1 | CodeableConcept | Type of measurement recording device Binding: KIOLA Measurement Device Types (required) Required Pattern: At least the following | ||||
|     id | 0..1 | string | Unique id for inter-element referencing | |||||
|     extension | 0..* | Extension | Additional content defined by implementations | |||||
|     coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
|      id | 0..1 | string | Unique id for inter-element referencing | |||||
|      extension | 0..* | Extension | Additional content defined by implementations | |||||
|      system | 1..1 | uri | Identity of the terminology system Fixed Value: https://fhir.ehealth-systems.at/kiola/device | |||||
|      version | 0..1 | string | Version of the system - if relevant | |||||
|      code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: SDC | |||||
|      display | 0..1 | string | Representation defined by the system | |||||
|      userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
|     text | 0..1 | string | Plain text representation of the concept | |||||
|    specialization | 0..* | BackboneElement | The capabilities supported on a  device, the standards to which the device conforms for a particular purpose, and used for the communication | |||||
|     id | 0..1 | string | Unique id for inter-element referencing | |||||
|     extension | 0..* | Extension | Additional content defined by implementations | |||||
|     modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
|     systemType | 1..1 | string | The standard that is used to operate and communicate | |||||
|     version | 0..1 | string | The version of the standard that is used to operate and communicate | |||||
|    version | 0..* | string | Available versions | |||||
|    safety | Σ | 0..* | CodeableConcept | Safety characteristics of the device Binding: device-safety (example) | ||||
|    shelfLifeStorage | 0..* | ProductShelfLife | Shelf Life and storage information | |||||
|    physicalCharacteristics | 0..1 | ProdCharacteristic | Dimensions, color etc. | |||||
|    languageCode | 0..* | CodeableConcept | Language code for the human-readable text strings produced by the device (all supported) | |||||
|    capability | 0..* | BackboneElement | Device capabilities | |||||
|     id | 0..1 | string | Unique id for inter-element referencing | |||||
|     extension | 0..* | Extension | Additional content defined by implementations | |||||
|     modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
|     type | 1..1 | CodeableConcept | Type of capability | |||||
|     description | 0..* | CodeableConcept | Description of capability | |||||
|    Slices for property | 0..* | BackboneElement | The actual configuration settings of a device as it actually operates, e.g., regulation status, time properties Slice: Unordered, Open by value:type | |||||
|     property:All Slices | Content/Rules for all slices | |||||||
|      id | 0..1 | string | Unique id for inter-element referencing | |||||
|      extension | 0..* | Extension | Additional content defined by implementations | |||||
|      modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
|      type | 1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) | |||||
|      valueQuantity | 0..* | Quantity | Property value as a quantity | |||||
|      valueCode | 0..* | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) | |||||
|     property:uiReference | S | 0..1 | BackboneElement | UI reference which is used to display the device on a client | ||||
|      id | 0..1 | string | Unique id for inter-element referencing | |||||
|      extension | 0..* | Extension | Additional content defined by implementations | |||||
|      modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
|      type | 1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) Required Pattern: At least the following | |||||
|       id | 0..1 | string | Unique id for inter-element referencing | |||||
|       extension | 0..* | Extension | Additional content defined by implementations | |||||
|       coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
|        id | 0..1 | string | Unique id for inter-element referencing | |||||
|        extension | 0..* | Extension | Additional content defined by implementations | |||||
|        system | 1..1 | uri | Identity of the terminology system Fixed Value: https://fhir.ehealth-systems.at/kiola/device/kmc | |||||
|        version | 0..1 | string | Version of the system - if relevant | |||||
|        code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: ui_reference | |||||
|        display | 0..1 | string | Representation defined by the system | |||||
|        userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
|       text | 0..1 | string | Plain text representation of the concept | |||||
|      valueCode | S | 1..1 | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) Binding: KMC UI References (example) | ||||
|    owner | 0..1 | Reference(Organization) | Organization responsible for device | |||||
|    contact | 0..* | ContactPoint | Details for human/organization for support | |||||
|    url | 0..1 | uri | Network address to contact device | |||||
|    onlineInformation | 0..1 | uri | Access to on-line information | |||||
|    note | 0..* | Annotation | Device notes and comments | |||||
|    quantity | 0..1 | Quantity | The quantity of the device present in the packaging (e.g. the number of devices present in a pack, or the number of devices in the same package of the medicinal product) | |||||
|    parentDevice | Σ | 0..1 | Reference(DeviceDefinition) | The parent device it can be part of | ||||
|    material | 0..* | BackboneElement | A substance used to create the material(s) of which the device is made | |||||
|     id | 0..1 | string | Unique id for inter-element referencing | |||||
|     extension | 0..* | Extension | Additional content defined by implementations | |||||
|     modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
|     substance | 1..1 | CodeableConcept | The substance | |||||
|     alternate | 0..1 | boolean | Indicates an alternative material of the device | |||||
|     allergenicIndicator | 0..1 | boolean | Whether the substance is a known or suspected allergen | |||||
|  Documentation for this format | ||||||||
| Path | Conformance | ValueSet / Code | URI | |||
| DeviceDefinition.language | preferred | CommonLanguages 
 http://hl7.org/fhir/ValueSet/languagesfrom the FHIR Standard | ||||
| DeviceDefinition.deviceName.type | required | DeviceNameType http://hl7.org/fhir/ValueSet/device-nametype|4.3.0from the FHIR Standard | ||||
| DeviceDefinition.type | required | Pattern: SDC https://fhir.ehealth-systems.at/artifacts/ValueSet/KIOLAMeasurementDeviceTypesfrom this IG | ||||
| DeviceDefinition.safety | example | http://hl7.org/fhir/ValueSet/device-safety http://hl7.org/fhir/ValueSet/device-safety | ||||
| DeviceDefinition.property:uiReference.valueCode | example | KMCUIReferences https://fhir.ehealth-systems.at/artifacts/ValueSet/KMCUIReferencesfrom this IG | 
This structure is derived from KIOLAMeasurementDeviceDefinition
Differential View
This structure is derived from KIOLAMeasurementDeviceDefinition
| Name | Flags | Card. | Type | Description & Constraints  | 
|---|---|---|---|---|
|   DeviceDefinition | KIOLAMeasurementDeviceDefinition | |||
|    type | 1..1 | CodeableConcept | Type of measurement recording device Required Pattern: At least the following | |
|     coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
|      system | 1..1 | uri | Identity of the terminology system Fixed Value: https://fhir.ehealth-systems.at/kiola/device | |
|      code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: SDC | |
|  Documentation for this format | ||||
Key Elements View
| Name | Flags | Card. | Type | Description & Constraints  | 
|---|---|---|---|---|
|   DeviceDefinition | 0..* | KIOLAMeasurementDeviceDefinition | An instance of a medical-related component of a medical device | |
|    implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created | 
|    modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored | 
|    type | S | 1..1 | CodeableConcept | Type of measurement recording device Binding: KIOLA Measurement Device Types (required) Required Pattern: At least the following | 
|     coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
|      system | 1..1 | uri | Identity of the terminology system Fixed Value: https://fhir.ehealth-systems.at/kiola/device | |
|      code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: SDC | |
|    Slices for property | 0..* | BackboneElement | The actual configuration settings of a device as it actually operates, e.g., regulation status, time properties Slice: Unordered, Open by value:type | |
|     property:All Slices | Content/Rules for all slices | |||
|      modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | 
|      type | 1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) | |
|     property:uiReference | S | 0..1 | BackboneElement | UI reference which is used to display the device on a client | 
|      modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | 
|      type | 1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) Required Pattern: At least the following | |
|       coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
|        system | 1..1 | uri | Identity of the terminology system Fixed Value: https://fhir.ehealth-systems.at/kiola/device/kmc | |
|        code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: ui_reference | |
|      valueCode | S | 1..1 | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) Binding: KMC UI References (example) | 
|  Documentation for this format | ||||
| Path | Conformance | ValueSet / Code | URI | 
| DeviceDefinition.type | required | Pattern: SDC https://fhir.ehealth-systems.at/artifacts/ValueSet/KIOLAMeasurementDeviceTypesfrom this IG | |
| DeviceDefinition.property:uiReference.valueCode | example | KMCUIReferences https://fhir.ehealth-systems.at/artifacts/ValueSet/KMCUIReferencesfrom this IG | 
Snapshot View
| Name | Flags | Card. | Type | Description & Constraints  | ||||
|---|---|---|---|---|---|---|---|---|
|   DeviceDefinition | 0..* | KIOLAMeasurementDeviceDefinition | An instance of a medical-related component of a medical device | |||||
|    id | Σ | 0..1 | id | Logical id of this artifact | ||||
|    meta | Σ | 0..1 | Meta | Metadata about the resource | ||||
|    implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||
|    language | 0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): IETF language tag 
 | |||||
|    text | 0..1 | Narrative | Text summary of the resource, for human interpretation | |||||
|    contained | 0..* | Resource | Contained, inline Resources dom-r4b: Containing new R4B resources within R4 resources may cause interoperability issues if instances are shared with R4 systems | |||||
|    extension | 0..* | Extension | Additional content defined by implementations | |||||
|    modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored | ||||
|    identifier | 0..* | Identifier | Instance identifier | |||||
|    udiDeviceIdentifier | 0..* | BackboneElement | Unique Device Identifier (UDI) Barcode string | |||||
|     id | 0..1 | string | Unique id for inter-element referencing | |||||
|     extension | 0..* | Extension | Additional content defined by implementations | |||||
|     modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
|     deviceIdentifier | 1..1 | string | The identifier that is to be associated with every Device that references this DeviceDefintiion for the issuer and jurisdication porvided in the DeviceDefinition.udiDeviceIdentifier | |||||
|     issuer | 1..1 | uri | The organization that assigns the identifier algorithm | |||||
|     jurisdiction | 1..1 | uri | The jurisdiction to which the deviceIdentifier applies | |||||
|    manufacturer[x] | 0..1 | Name of device manufacturer | ||||||
|     manufacturerString | string | |||||||
|     manufacturerReference | Reference(Organization) | |||||||
|    deviceName | 0..* | BackboneElement | A name given to the device to identify it | |||||
|     id | 0..1 | string | Unique id for inter-element referencing | |||||
|     extension | 0..* | Extension | Additional content defined by implementations | |||||
|     modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
|     name | 1..1 | string | The name of the device | |||||
|     type | 1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Binding: DeviceNameType (required): The type of name the device is referred by. | |||||
|    modelNumber | 0..1 | string | The model number for the device | |||||
|    type | S | 1..1 | CodeableConcept | Type of measurement recording device Binding: KIOLA Measurement Device Types (required) Required Pattern: At least the following | ||||
|     id | 0..1 | string | Unique id for inter-element referencing | |||||
|     extension | 0..* | Extension | Additional content defined by implementations | |||||
|     coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
|      id | 0..1 | string | Unique id for inter-element referencing | |||||
|      extension | 0..* | Extension | Additional content defined by implementations | |||||
|      system | 1..1 | uri | Identity of the terminology system Fixed Value: https://fhir.ehealth-systems.at/kiola/device | |||||
|      version | 0..1 | string | Version of the system - if relevant | |||||
|      code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: SDC | |||||
|      display | 0..1 | string | Representation defined by the system | |||||
|      userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
|     text | 0..1 | string | Plain text representation of the concept | |||||
|    specialization | 0..* | BackboneElement | The capabilities supported on a  device, the standards to which the device conforms for a particular purpose, and used for the communication | |||||
|     id | 0..1 | string | Unique id for inter-element referencing | |||||
|     extension | 0..* | Extension | Additional content defined by implementations | |||||
|     modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
|     systemType | 1..1 | string | The standard that is used to operate and communicate | |||||
|     version | 0..1 | string | The version of the standard that is used to operate and communicate | |||||
|    version | 0..* | string | Available versions | |||||
|    safety | Σ | 0..* | CodeableConcept | Safety characteristics of the device Binding: device-safety (example) | ||||
|    shelfLifeStorage | 0..* | ProductShelfLife | Shelf Life and storage information | |||||
|    physicalCharacteristics | 0..1 | ProdCharacteristic | Dimensions, color etc. | |||||
|    languageCode | 0..* | CodeableConcept | Language code for the human-readable text strings produced by the device (all supported) | |||||
|    capability | 0..* | BackboneElement | Device capabilities | |||||
|     id | 0..1 | string | Unique id for inter-element referencing | |||||
|     extension | 0..* | Extension | Additional content defined by implementations | |||||
|     modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
|     type | 1..1 | CodeableConcept | Type of capability | |||||
|     description | 0..* | CodeableConcept | Description of capability | |||||
|    Slices for property | 0..* | BackboneElement | The actual configuration settings of a device as it actually operates, e.g., regulation status, time properties Slice: Unordered, Open by value:type | |||||
|     property:All Slices | Content/Rules for all slices | |||||||
|      id | 0..1 | string | Unique id for inter-element referencing | |||||
|      extension | 0..* | Extension | Additional content defined by implementations | |||||
|      modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
|      type | 1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) | |||||
|      valueQuantity | 0..* | Quantity | Property value as a quantity | |||||
|      valueCode | 0..* | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) | |||||
|     property:uiReference | S | 0..1 | BackboneElement | UI reference which is used to display the device on a client | ||||
|      id | 0..1 | string | Unique id for inter-element referencing | |||||
|      extension | 0..* | Extension | Additional content defined by implementations | |||||
|      modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
|      type | 1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) Required Pattern: At least the following | |||||
|       id | 0..1 | string | Unique id for inter-element referencing | |||||
|       extension | 0..* | Extension | Additional content defined by implementations | |||||
|       coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
|        id | 0..1 | string | Unique id for inter-element referencing | |||||
|        extension | 0..* | Extension | Additional content defined by implementations | |||||
|        system | 1..1 | uri | Identity of the terminology system Fixed Value: https://fhir.ehealth-systems.at/kiola/device/kmc | |||||
|        version | 0..1 | string | Version of the system - if relevant | |||||
|        code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: ui_reference | |||||
|        display | 0..1 | string | Representation defined by the system | |||||
|        userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
|       text | 0..1 | string | Plain text representation of the concept | |||||
|      valueCode | S | 1..1 | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) Binding: KMC UI References (example) | ||||
|    owner | 0..1 | Reference(Organization) | Organization responsible for device | |||||
|    contact | 0..* | ContactPoint | Details for human/organization for support | |||||
|    url | 0..1 | uri | Network address to contact device | |||||
|    onlineInformation | 0..1 | uri | Access to on-line information | |||||
|    note | 0..* | Annotation | Device notes and comments | |||||
|    quantity | 0..1 | Quantity | The quantity of the device present in the packaging (e.g. the number of devices present in a pack, or the number of devices in the same package of the medicinal product) | |||||
|    parentDevice | Σ | 0..1 | Reference(DeviceDefinition) | The parent device it can be part of | ||||
|    material | 0..* | BackboneElement | A substance used to create the material(s) of which the device is made | |||||
|     id | 0..1 | string | Unique id for inter-element referencing | |||||
|     extension | 0..* | Extension | Additional content defined by implementations | |||||
|     modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
|     substance | 1..1 | CodeableConcept | The substance | |||||
|     alternate | 0..1 | boolean | Indicates an alternative material of the device | |||||
|     allergenicIndicator | 0..1 | boolean | Whether the substance is a known or suspected allergen | |||||
|  Documentation for this format | ||||||||
| Path | Conformance | ValueSet / Code | URI | |||
| DeviceDefinition.language | preferred | CommonLanguages 
 http://hl7.org/fhir/ValueSet/languagesfrom the FHIR Standard | ||||
| DeviceDefinition.deviceName.type | required | DeviceNameType http://hl7.org/fhir/ValueSet/device-nametype|4.3.0from the FHIR Standard | ||||
| DeviceDefinition.type | required | Pattern: SDC https://fhir.ehealth-systems.at/artifacts/ValueSet/KIOLAMeasurementDeviceTypesfrom this IG | ||||
| DeviceDefinition.safety | example | http://hl7.org/fhir/ValueSet/device-safety http://hl7.org/fhir/ValueSet/device-safety | ||||
| DeviceDefinition.property:uiReference.valueCode | example | KMCUIReferences https://fhir.ehealth-systems.at/artifacts/ValueSet/KMCUIReferencesfrom this IG | 
This structure is derived from KIOLAMeasurementDeviceDefinition
Other representations of profile: CSV, Excel, Schematron