Device supporting manual data entry of KIOLA vital data measurements.
Usage:
Description of Profiles, Differentials, Snapshots and how the different presentations work.
This structure is derived from KIOLAMeasurementDevice
| Name | Flags | Card. | Type | Description & Constraints  | 
|---|---|---|---|---|
|   Device | KIOLAMeasurementDevice | |||
|    definition | 0..1 | Reference(KIOLA Measurement Manual Entry Device Definition) | The reference to the definition for the device | |
|    type | 1..1 | CodeableConcept | Type of measurement recording device Required Pattern: At least the following | |
|     coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
|      system | 1..1 | uri | Identity of the terminology system Fixed Value: https://fhir.ehealth-systems.at/kiola/device | |
|      code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: SDC | |
|  Documentation for this format | ||||
| Name | Flags | Card. | Type | Description & Constraints  | 
|---|---|---|---|---|
|   Device | 0..* | KIOLAMeasurementDevice | Item used in healthcare | |
|    implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created | 
|    modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored | 
|    definition | 0..1 | Reference(KIOLA Measurement Manual Entry Device Definition) | The reference to the definition for the device | |
|    status | ?!Σ | 0..1 | code | active | inactive | entered-in-error | unknown Binding: FHIRDeviceStatus (required): The availability status of the device. | 
|    type | S | 1..1 | CodeableConcept | Type of measurement recording device Binding: KIOLA Measurement Device Types (required) Required Pattern: At least the following | 
|     coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
|      system | 1..1 | uri | Identity of the terminology system Fixed Value: https://fhir.ehealth-systems.at/kiola/device | |
|      code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: SDC | |
|    Slices for property | 0..* | BackboneElement | The actual configuration settings of a device as it actually operates, e.g., regulation status, time properties Slice: Unordered, Open by value:type | |
|     property:All Slices | Content/Rules for all slices | |||
|      modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | 
|      type | 1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) | |
|     property:uiReference | S | 0..1 | BackboneElement | UI reference which is used to display the device on a client | 
|      modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | 
|      type | 1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) Required Pattern: At least the following | |
|       coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
|        system | 1..1 | uri | Identity of the terminology system Fixed Value: https://fhir.ehealth-systems.at/kiola/device/kmc | |
|        code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: ui_reference | |
|      valueCode | S | 1..1 | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) Binding: KMC UI References (example) | 
|  Documentation for this format | ||||
| Path | Conformance | ValueSet / Code | URI | 
| Device.status | required | FHIRDeviceStatus http://hl7.org/fhir/ValueSet/device-status|4.3.0from the FHIR Standard | |
| Device.type | required | Pattern: SDC https://fhir.ehealth-systems.at/artifacts/ValueSet/KIOLAMeasurementDeviceTypesfrom this IG | |
| Device.property:uiReference.valueCode | example | KMCUIReferences https://fhir.ehealth-systems.at/artifacts/ValueSet/KMCUIReferencesfrom this IG | 
| Name | Flags | Card. | Type | Description & Constraints  | ||||
|---|---|---|---|---|---|---|---|---|
|   Device | 0..* | KIOLAMeasurementDevice | Item used in healthcare | |||||
|    id | Σ | 0..1 | id | Logical id of this artifact | ||||
|    meta | Σ | 0..1 | Meta | Metadata about the resource | ||||
|    implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||
|    language | 0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): IETF language tag 
 | |||||
|    text | 0..1 | Narrative | Text summary of the resource, for human interpretation | |||||
|    contained | 0..* | Resource | Contained, inline Resources dom-r4b: Containing new R4B resources within R4 resources may cause interoperability issues if instances are shared with R4 systems | |||||
|    extension | 0..* | Extension | Additional content defined by implementations | |||||
|    modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored | ||||
|    identifier | 0..* | Identifier | Instance identifier | |||||
|    definition | 0..1 | Reference(KIOLA Measurement Manual Entry Device Definition) | The reference to the definition for the device | |||||
|    udiCarrier | Σ | 0..* | BackboneElement | Unique Device Identifier (UDI) Barcode string | ||||
|     id | 0..1 | string | Unique id for inter-element referencing | |||||
|     extension | 0..* | Extension | Additional content defined by implementations | |||||
|     modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
|     deviceIdentifier | Σ | 0..1 | string | Mandatory fixed portion of UDI | ||||
|     issuer | 0..1 | uri | UDI Issuing Organization | |||||
|     jurisdiction | 0..1 | uri | Regional UDI authority | |||||
|     carrierAIDC | Σ | 0..1 | base64Binary | UDI Machine Readable Barcode String | ||||
|     carrierHRF | Σ | 0..1 | string | UDI Human Readable Barcode String | ||||
|     entryType | 0..1 | code | barcode | rfid | manual + Binding: UDIEntryType (required): Codes to identify how UDI data was entered. | |||||
|    status | ?!Σ | 0..1 | code | active | inactive | entered-in-error | unknown Binding: FHIRDeviceStatus (required): The availability status of the device. | ||||
|    statusReason | 0..* | CodeableConcept | online | paused | standby | offline | not-ready | transduc-discon | hw-discon | off Binding: FHIRDeviceStatusReason (extensible): The availability status reason of the device. | |||||
|    distinctIdentifier | 0..1 | string | The distinct identification string | |||||
|    manufacturer | 0..1 | string | Name of device manufacturer | |||||
|    manufactureDate | 0..1 | dateTime | Date when the device was made | |||||
|    expirationDate | 0..1 | dateTime | Date and time of expiry of this device (if applicable) | |||||
|    lotNumber | 0..1 | string | Lot number of manufacture | |||||
|    serialNumber | 0..1 | string | Serial number assigned by the manufacturer | |||||
|    deviceName | 0..* | BackboneElement | The name of the device as given by the manufacturer | |||||
|     id | 0..1 | string | Unique id for inter-element referencing | |||||
|     extension | 0..* | Extension | Additional content defined by implementations | |||||
|     modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
|     name | 1..1 | string | The name that identifies the device | |||||
|     type | 1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Binding: DeviceNameType (required): The type of name the device is referred by. | |||||
|    modelNumber | 0..1 | string | The manufacturer's model number for the device | |||||
|    partNumber | 0..1 | string | The part number or catalog number of the device | |||||
|    type | S | 1..1 | CodeableConcept | Type of measurement recording device Binding: KIOLA Measurement Device Types (required) Required Pattern: At least the following | ||||
|     id | 0..1 | string | Unique id for inter-element referencing | |||||
|     extension | 0..* | Extension | Additional content defined by implementations | |||||
|     coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
|      id | 0..1 | string | Unique id for inter-element referencing | |||||
|      extension | 0..* | Extension | Additional content defined by implementations | |||||
|      system | 1..1 | uri | Identity of the terminology system Fixed Value: https://fhir.ehealth-systems.at/kiola/device | |||||
|      version | 0..1 | string | Version of the system - if relevant | |||||
|      code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: SDC | |||||
|      display | 0..1 | string | Representation defined by the system | |||||
|      userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
|     text | 0..1 | string | Plain text representation of the concept | |||||
|    specialization | 0..* | BackboneElement | The capabilities supported on a  device, the standards to which the device conforms for a particular purpose, and used for the communication | |||||
|     id | 0..1 | string | Unique id for inter-element referencing | |||||
|     extension | 0..* | Extension | Additional content defined by implementations | |||||
|     modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
|     systemType | 1..1 | CodeableConcept | The standard that is used to operate and communicate | |||||
|     version | 0..1 | string | The version of the standard that is used to operate and communicate | |||||
|    version | 0..* | BackboneElement | The actual design of the device or software version running on the device | |||||
|     id | 0..1 | string | Unique id for inter-element referencing | |||||
|     extension | 0..* | Extension | Additional content defined by implementations | |||||
|     modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
|     type | 0..1 | CodeableConcept | The type of the device version, e.g. manufacturer, approved, internal | |||||
|     component | 0..1 | Identifier | A single component of the device version | |||||
|     value | 1..1 | string | The version text | |||||
|    Slices for property | 0..* | BackboneElement | The actual configuration settings of a device as it actually operates, e.g., regulation status, time properties Slice: Unordered, Open by value:type | |||||
|     property:All Slices | Content/Rules for all slices | |||||||
|      id | 0..1 | string | Unique id for inter-element referencing | |||||
|      extension | 0..* | Extension | Additional content defined by implementations | |||||
|      modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
|      type | 1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) | |||||
|      valueQuantity | 0..* | Quantity | Property value as a quantity | |||||
|      valueCode | 0..* | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) | |||||
|     property:uiReference | S | 0..1 | BackboneElement | UI reference which is used to display the device on a client | ||||
|      id | 0..1 | string | Unique id for inter-element referencing | |||||
|      extension | 0..* | Extension | Additional content defined by implementations | |||||
|      modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
|      type | 1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) Required Pattern: At least the following | |||||
|       id | 0..1 | string | Unique id for inter-element referencing | |||||
|       extension | 0..* | Extension | Additional content defined by implementations | |||||
|       coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
|        id | 0..1 | string | Unique id for inter-element referencing | |||||
|        extension | 0..* | Extension | Additional content defined by implementations | |||||
|        system | 1..1 | uri | Identity of the terminology system Fixed Value: https://fhir.ehealth-systems.at/kiola/device/kmc | |||||
|        version | 0..1 | string | Version of the system - if relevant | |||||
|        code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: ui_reference | |||||
|        display | 0..1 | string | Representation defined by the system | |||||
|        userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
|       text | 0..1 | string | Plain text representation of the concept | |||||
|      valueCode | S | 1..1 | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) Binding: KMC UI References (example) | ||||
|    patient | 0..1 | Reference(Patient) | Patient to whom Device is affixed | |||||
|    owner | 0..1 | Reference(Organization) | Organization responsible for device | |||||
|    contact | 0..* | ContactPoint | Details for human/organization for support | |||||
|    location | 0..1 | Reference(Location) | Where the device is found | |||||
|    url | 0..1 | uri | Network address to contact device | |||||
|    note | 0..* | Annotation | Device notes and comments | |||||
|    safety | Σ | 0..* | CodeableConcept | Safety Characteristics of Device | ||||
|    parent | 0..1 | Reference(Device) | The device that this device is attached to or is part of | |||||
|  Documentation for this format | ||||||||
| Path | Conformance | ValueSet / Code | URI | |||
| Device.language | preferred | CommonLanguages 
 http://hl7.org/fhir/ValueSet/languagesfrom the FHIR Standard | ||||
| Device.udiCarrier.entryType | required | UDIEntryType http://hl7.org/fhir/ValueSet/udi-entry-type|4.3.0from the FHIR Standard | ||||
| Device.status | required | FHIRDeviceStatus http://hl7.org/fhir/ValueSet/device-status|4.3.0from the FHIR Standard | ||||
| Device.statusReason | extensible | FHIRDeviceStatusReason http://hl7.org/fhir/ValueSet/device-status-reasonfrom the FHIR Standard | ||||
| Device.deviceName.type | required | DeviceNameType http://hl7.org/fhir/ValueSet/device-nametype|4.3.0from the FHIR Standard | ||||
| Device.type | required | Pattern: SDC https://fhir.ehealth-systems.at/artifacts/ValueSet/KIOLAMeasurementDeviceTypesfrom this IG | ||||
| Device.property:uiReference.valueCode | example | KMCUIReferences https://fhir.ehealth-systems.at/artifacts/ValueSet/KMCUIReferencesfrom this IG | 
This structure is derived from KIOLAMeasurementDevice
Differential View
This structure is derived from KIOLAMeasurementDevice
| Name | Flags | Card. | Type | Description & Constraints  | 
|---|---|---|---|---|
|   Device | KIOLAMeasurementDevice | |||
|    definition | 0..1 | Reference(KIOLA Measurement Manual Entry Device Definition) | The reference to the definition for the device | |
|    type | 1..1 | CodeableConcept | Type of measurement recording device Required Pattern: At least the following | |
|     coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
|      system | 1..1 | uri | Identity of the terminology system Fixed Value: https://fhir.ehealth-systems.at/kiola/device | |
|      code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: SDC | |
|  Documentation for this format | ||||
Key Elements View
| Name | Flags | Card. | Type | Description & Constraints  | 
|---|---|---|---|---|
|   Device | 0..* | KIOLAMeasurementDevice | Item used in healthcare | |
|    implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created | 
|    modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored | 
|    definition | 0..1 | Reference(KIOLA Measurement Manual Entry Device Definition) | The reference to the definition for the device | |
|    status | ?!Σ | 0..1 | code | active | inactive | entered-in-error | unknown Binding: FHIRDeviceStatus (required): The availability status of the device. | 
|    type | S | 1..1 | CodeableConcept | Type of measurement recording device Binding: KIOLA Measurement Device Types (required) Required Pattern: At least the following | 
|     coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
|      system | 1..1 | uri | Identity of the terminology system Fixed Value: https://fhir.ehealth-systems.at/kiola/device | |
|      code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: SDC | |
|    Slices for property | 0..* | BackboneElement | The actual configuration settings of a device as it actually operates, e.g., regulation status, time properties Slice: Unordered, Open by value:type | |
|     property:All Slices | Content/Rules for all slices | |||
|      modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | 
|      type | 1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) | |
|     property:uiReference | S | 0..1 | BackboneElement | UI reference which is used to display the device on a client | 
|      modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | 
|      type | 1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) Required Pattern: At least the following | |
|       coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
|        system | 1..1 | uri | Identity of the terminology system Fixed Value: https://fhir.ehealth-systems.at/kiola/device/kmc | |
|        code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: ui_reference | |
|      valueCode | S | 1..1 | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) Binding: KMC UI References (example) | 
|  Documentation for this format | ||||
| Path | Conformance | ValueSet / Code | URI | 
| Device.status | required | FHIRDeviceStatus http://hl7.org/fhir/ValueSet/device-status|4.3.0from the FHIR Standard | |
| Device.type | required | Pattern: SDC https://fhir.ehealth-systems.at/artifacts/ValueSet/KIOLAMeasurementDeviceTypesfrom this IG | |
| Device.property:uiReference.valueCode | example | KMCUIReferences https://fhir.ehealth-systems.at/artifacts/ValueSet/KMCUIReferencesfrom this IG | 
Snapshot View
| Name | Flags | Card. | Type | Description & Constraints  | ||||
|---|---|---|---|---|---|---|---|---|
|   Device | 0..* | KIOLAMeasurementDevice | Item used in healthcare | |||||
|    id | Σ | 0..1 | id | Logical id of this artifact | ||||
|    meta | Σ | 0..1 | Meta | Metadata about the resource | ||||
|    implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||
|    language | 0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): IETF language tag 
 | |||||
|    text | 0..1 | Narrative | Text summary of the resource, for human interpretation | |||||
|    contained | 0..* | Resource | Contained, inline Resources dom-r4b: Containing new R4B resources within R4 resources may cause interoperability issues if instances are shared with R4 systems | |||||
|    extension | 0..* | Extension | Additional content defined by implementations | |||||
|    modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored | ||||
|    identifier | 0..* | Identifier | Instance identifier | |||||
|    definition | 0..1 | Reference(KIOLA Measurement Manual Entry Device Definition) | The reference to the definition for the device | |||||
|    udiCarrier | Σ | 0..* | BackboneElement | Unique Device Identifier (UDI) Barcode string | ||||
|     id | 0..1 | string | Unique id for inter-element referencing | |||||
|     extension | 0..* | Extension | Additional content defined by implementations | |||||
|     modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
|     deviceIdentifier | Σ | 0..1 | string | Mandatory fixed portion of UDI | ||||
|     issuer | 0..1 | uri | UDI Issuing Organization | |||||
|     jurisdiction | 0..1 | uri | Regional UDI authority | |||||
|     carrierAIDC | Σ | 0..1 | base64Binary | UDI Machine Readable Barcode String | ||||
|     carrierHRF | Σ | 0..1 | string | UDI Human Readable Barcode String | ||||
|     entryType | 0..1 | code | barcode | rfid | manual + Binding: UDIEntryType (required): Codes to identify how UDI data was entered. | |||||
|    status | ?!Σ | 0..1 | code | active | inactive | entered-in-error | unknown Binding: FHIRDeviceStatus (required): The availability status of the device. | ||||
|    statusReason | 0..* | CodeableConcept | online | paused | standby | offline | not-ready | transduc-discon | hw-discon | off Binding: FHIRDeviceStatusReason (extensible): The availability status reason of the device. | |||||
|    distinctIdentifier | 0..1 | string | The distinct identification string | |||||
|    manufacturer | 0..1 | string | Name of device manufacturer | |||||
|    manufactureDate | 0..1 | dateTime | Date when the device was made | |||||
|    expirationDate | 0..1 | dateTime | Date and time of expiry of this device (if applicable) | |||||
|    lotNumber | 0..1 | string | Lot number of manufacture | |||||
|    serialNumber | 0..1 | string | Serial number assigned by the manufacturer | |||||
|    deviceName | 0..* | BackboneElement | The name of the device as given by the manufacturer | |||||
|     id | 0..1 | string | Unique id for inter-element referencing | |||||
|     extension | 0..* | Extension | Additional content defined by implementations | |||||
|     modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
|     name | 1..1 | string | The name that identifies the device | |||||
|     type | 1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Binding: DeviceNameType (required): The type of name the device is referred by. | |||||
|    modelNumber | 0..1 | string | The manufacturer's model number for the device | |||||
|    partNumber | 0..1 | string | The part number or catalog number of the device | |||||
|    type | S | 1..1 | CodeableConcept | Type of measurement recording device Binding: KIOLA Measurement Device Types (required) Required Pattern: At least the following | ||||
|     id | 0..1 | string | Unique id for inter-element referencing | |||||
|     extension | 0..* | Extension | Additional content defined by implementations | |||||
|     coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
|      id | 0..1 | string | Unique id for inter-element referencing | |||||
|      extension | 0..* | Extension | Additional content defined by implementations | |||||
|      system | 1..1 | uri | Identity of the terminology system Fixed Value: https://fhir.ehealth-systems.at/kiola/device | |||||
|      version | 0..1 | string | Version of the system - if relevant | |||||
|      code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: SDC | |||||
|      display | 0..1 | string | Representation defined by the system | |||||
|      userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
|     text | 0..1 | string | Plain text representation of the concept | |||||
|    specialization | 0..* | BackboneElement | The capabilities supported on a  device, the standards to which the device conforms for a particular purpose, and used for the communication | |||||
|     id | 0..1 | string | Unique id for inter-element referencing | |||||
|     extension | 0..* | Extension | Additional content defined by implementations | |||||
|     modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
|     systemType | 1..1 | CodeableConcept | The standard that is used to operate and communicate | |||||
|     version | 0..1 | string | The version of the standard that is used to operate and communicate | |||||
|    version | 0..* | BackboneElement | The actual design of the device or software version running on the device | |||||
|     id | 0..1 | string | Unique id for inter-element referencing | |||||
|     extension | 0..* | Extension | Additional content defined by implementations | |||||
|     modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
|     type | 0..1 | CodeableConcept | The type of the device version, e.g. manufacturer, approved, internal | |||||
|     component | 0..1 | Identifier | A single component of the device version | |||||
|     value | 1..1 | string | The version text | |||||
|    Slices for property | 0..* | BackboneElement | The actual configuration settings of a device as it actually operates, e.g., regulation status, time properties Slice: Unordered, Open by value:type | |||||
|     property:All Slices | Content/Rules for all slices | |||||||
|      id | 0..1 | string | Unique id for inter-element referencing | |||||
|      extension | 0..* | Extension | Additional content defined by implementations | |||||
|      modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
|      type | 1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) | |||||
|      valueQuantity | 0..* | Quantity | Property value as a quantity | |||||
|      valueCode | 0..* | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) | |||||
|     property:uiReference | S | 0..1 | BackboneElement | UI reference which is used to display the device on a client | ||||
|      id | 0..1 | string | Unique id for inter-element referencing | |||||
|      extension | 0..* | Extension | Additional content defined by implementations | |||||
|      modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
|      type | 1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) Required Pattern: At least the following | |||||
|       id | 0..1 | string | Unique id for inter-element referencing | |||||
|       extension | 0..* | Extension | Additional content defined by implementations | |||||
|       coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
|        id | 0..1 | string | Unique id for inter-element referencing | |||||
|        extension | 0..* | Extension | Additional content defined by implementations | |||||
|        system | 1..1 | uri | Identity of the terminology system Fixed Value: https://fhir.ehealth-systems.at/kiola/device/kmc | |||||
|        version | 0..1 | string | Version of the system - if relevant | |||||
|        code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: ui_reference | |||||
|        display | 0..1 | string | Representation defined by the system | |||||
|        userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
|       text | 0..1 | string | Plain text representation of the concept | |||||
|      valueCode | S | 1..1 | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) Binding: KMC UI References (example) | ||||
|    patient | 0..1 | Reference(Patient) | Patient to whom Device is affixed | |||||
|    owner | 0..1 | Reference(Organization) | Organization responsible for device | |||||
|    contact | 0..* | ContactPoint | Details for human/organization for support | |||||
|    location | 0..1 | Reference(Location) | Where the device is found | |||||
|    url | 0..1 | uri | Network address to contact device | |||||
|    note | 0..* | Annotation | Device notes and comments | |||||
|    safety | Σ | 0..* | CodeableConcept | Safety Characteristics of Device | ||||
|    parent | 0..1 | Reference(Device) | The device that this device is attached to or is part of | |||||
|  Documentation for this format | ||||||||
| Path | Conformance | ValueSet / Code | URI | |||
| Device.language | preferred | CommonLanguages 
 http://hl7.org/fhir/ValueSet/languagesfrom the FHIR Standard | ||||
| Device.udiCarrier.entryType | required | UDIEntryType http://hl7.org/fhir/ValueSet/udi-entry-type|4.3.0from the FHIR Standard | ||||
| Device.status | required | FHIRDeviceStatus http://hl7.org/fhir/ValueSet/device-status|4.3.0from the FHIR Standard | ||||
| Device.statusReason | extensible | FHIRDeviceStatusReason http://hl7.org/fhir/ValueSet/device-status-reasonfrom the FHIR Standard | ||||
| Device.deviceName.type | required | DeviceNameType http://hl7.org/fhir/ValueSet/device-nametype|4.3.0from the FHIR Standard | ||||
| Device.type | required | Pattern: SDC https://fhir.ehealth-systems.at/artifacts/ValueSet/KIOLAMeasurementDeviceTypesfrom this IG | ||||
| Device.property:uiReference.valueCode | example | KMCUIReferences https://fhir.ehealth-systems.at/artifacts/ValueSet/KMCUIReferencesfrom this IG | 
This structure is derived from KIOLAMeasurementDevice
Other representations of profile: CSV, Excel, Schematron